Effect of Plasma Hardening on Chromium Steel Corrosion Resistance
- Авторлар: Korotkov V.A.1
-
Мекемелер:
- Nizhnii Tagil Branch, Ural Federal University
- Шығарылым: Том 53, № 9-10 (2018)
- Беттер: 627-630
- Бөлім: Article
- URL: https://journal-vniispk.ru/0009-2355/article/view/235921
- DOI: https://doi.org/10.1007/s10556-018-0392-4
- ID: 235921
Дәйексөз келтіру
Аннотация
Plasma hardening by a standard UDGZ-200 unit makes it possible to provide not only a marked increase in steel 20Kh13 hardness and wear resistance, but also an improvement of corrosion resistance. Under experimental conditions, the corrosion resistance of steel 20Kh13 after hardening increased by a factor of 1.86, but decreased somewhat (by 15%) in the transition area to unhardened metal.
Негізгі сөздер
Авторлар туралы
V. Korotkov
Nizhnii Tagil Branch, Ural Federal University
Хат алмасуға жауапты Автор.
Email: vk@udgz.ru
Ресей, Nizhnii Tagil