Method of Harmonic Balance in Full-Scale-Model Tests of Electrical Devices


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Methods for determining the weber-ampere characteristics of electrical devices, one of which is based on solution of direct problem of harmonic balance and the other on solution of inverse problem of harmonic balance by the method of full-scale-model tests, are suggested. The mathematical model of the device is constructed using the describing function and simplex optimization methods. The presented results of experimental applications of the method show its efficiency. The advantage of the method is the possibility of application for nondestructive inspection of electrical devices in the processes of their production and operation.

About the authors

N. I. Gorbatenko

M. I. Platov South-Russian State Polytechnic University (NPI)

Email: lankinjohn@rambler.ru
Russian Federation, Novocherkassk

A. M. Lankin

M. I. Platov South-Russian State Polytechnic University (NPI)

Email: lankinjohn@rambler.ru
Russian Federation, Novocherkassk

M. V. Lankin

M. I. Platov South-Russian State Polytechnic University (NPI)

Author for correspondence.
Email: lankinjohn@rambler.ru
Russian Federation, Novocherkassk

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2017 Springer Science+Business Media New York