Cooling of the Tuyere Belt of Horizontal Furnaces
- Autores: Bulatov K.V.1, Yakornov S.A.1, Skopin D.Y.1, Barsukov N.M.2
-
Afiliações:
- Mednogorsk Copper-Sulfur Combine
- Prommet Company
- Edição: Volume 60, Nº 1-2 (2016)
- Páginas: 93-98
- Seção: Article
- URL: https://journal-vniispk.ru/0026-0894/article/view/238037
- DOI: https://doi.org/10.1007/s11015-016-0257-z
- ID: 238037
Citar
Resumo
To reduce the rate of erosion of tuyere-zone refractories in horizontal converters and furnaces that serve as melters and converters, a study is made of the effect of the average thermal conductivity of the protective layer in front of the cooled elements on layer’s erosion rate when an explosion-proof vacuum water-cooling system is in use. Results are presented on the thermal performance of the tuyere belt and the rate of erosion of layers having different values for thermal conductivity. It is shown that erosion of the protective layer is slowed by increasing its average thermal conductivity.
Palavras-chave
Sobre autores
K. Bulatov
Mednogorsk Copper-Sulfur Combine
Email: info@metallurgizdat.com
Rússia, Mednogorsk
S. Yakornov
Mednogorsk Copper-Sulfur Combine
Email: info@metallurgizdat.com
Rússia, Mednogorsk
D. Skopin
Mednogorsk Copper-Sulfur Combine
Email: info@metallurgizdat.com
Rússia, Mednogorsk
N. Barsukov
Prommet Company
Email: info@metallurgizdat.com
Rússia, St. Petersburg
Arquivos suplementares