Effect of water chemistry upsets on the dynamics of corrective reagent dosing systems at thermal power stations
- 作者: Voronov V.N.1, Yegoshina O.V.1, Bolshakova N.A.1, Yarovoi V.O.1, Latt A.M.1
-
隶属关系:
- Moscow Power Engineering Institute
- 期: 卷 63, 编号 12 (2016)
- 页面: 903-907
- 栏目: Water Treatment and Water Chemistry
- URL: https://journal-vniispk.ru/0040-6015/article/view/172480
- DOI: https://doi.org/10.1134/S0040601516120090
- ID: 172480
如何引用文章
详细
Typical disturbances in the dynamics of a corrective reagent dosing system under unsteady-state conditions during the unsatisfactory operation of a chemical control system with some water chemistry upsets at thermal and nuclear power stations are considered. An experimental setup representing a physical model for the water chemistry control system is described. The two disturbances, which are most frequently encountered in water chemistry control practice, such as a breakdown or shutdown of temperature compensation during pH measurement and an increase in the heat-transfer fluid flow rate, have been modeled in the process of study. The study of the effect produced by the response characteristics of chemical control analyzers on the operation of a reagent dosing system under unsteady-state conditions is important for the operative control of a water chemistry regime state. The effect of temperature compensation during pH measurement on the dynamics of an ammonia-dosing system in the manual and automatic cycle chemistry control modes has been studied. It has been demonstrated that the reading settling time of a pH meter in the manual ammonia- dosing mode grows with a breakdown in temperature compensation and a simultaneous increase in the temperature of a heat-transfer fluid sample. To improve the efficiency of water chemistry control, some systems for the quality control of a heat-transfer fluid by a chemical parameter with the obligatory compensation of a disturbance in its flow rate have been proposed for use. Experimental results will possibly differ from industrial data due to a great length of sampling lines. For this reason, corrective reagent dosing systems must be adapted to the conditions of a certain power-generating unit in the process of their implementation.
作者简介
V. Voronov
Moscow Power Engineering Institute
Email: yegoshinaov@gmail.com
俄罗斯联邦, ul. Krasnokazarmennaya 14, Moscow, 111250
O. Yegoshina
Moscow Power Engineering Institute
编辑信件的主要联系方式.
Email: yegoshinaov@gmail.com
俄罗斯联邦, ul. Krasnokazarmennaya 14, Moscow, 111250
N. Bolshakova
Moscow Power Engineering Institute
Email: yegoshinaov@gmail.com
俄罗斯联邦, ul. Krasnokazarmennaya 14, Moscow, 111250
V. Yarovoi
Moscow Power Engineering Institute
Email: yegoshinaov@gmail.com
俄罗斯联邦, ul. Krasnokazarmennaya 14, Moscow, 111250
Aie Latt
Moscow Power Engineering Institute
Email: yegoshinaov@gmail.com
俄罗斯联邦, ul. Krasnokazarmennaya 14, Moscow, 111250
补充文件