Remote Identification of Liquids in a Dielectric Container Using Millimeter Waves. 2. Linear Scanning
- Авторы: Pavlyuchenko A.V.1, Loshitskiy P.P.2, Shelengovskiy A.I.1, Babenko V.V.1
- 
							Учреждения: 
							- State Research Center “Iceberg”
- National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”
 
- Выпуск: Том 61, № 4 (2018)
- Страницы: 157-167
- Раздел: Article
- URL: https://journal-vniispk.ru/0735-2727/article/view/177200
- DOI: https://doi.org/10.3103/S0735272718040039
- ID: 177200
Цитировать
Аннотация
The results of experimental studies showing the applicability of short-range radar in the millimeter wavelength range for remote identification of explosive liquids in closed dielectric containers are presented. This study presents radiometric study of hazardous liquids based on an example of gasolines and diesel fuels. It has been shown experimentally that radiometric studies allow remote studies and object identification at distances of up to several meters. The variety of physical and chemical properties of liquid fuels does not allow their identification using the measurement results of only the permittivity and loss tangent from one measurement in one frequency range. The use of a thermal portrait of liquid fuels in closed dielectric containers for their identification is more illustrative and informative. The dependence of the spatial temperature portrait of the container with liquid on the polarization of the received signal is experimentally shown. The use of different polarizations of the received signal and the difference in the spatial temperature portraits of the liquid in the container provide additional information in order to increase the probability of correct identification of the liquid. Thermal portraits obtained with linear scanning for gasolines of different manufacturers differ more strongly, in comparison with thermal portraits of diesel fuels. Due to the modification of the measuring system, the total time for scanning and obtaining the output experimental data is 42 s. The standard deviation of the obtained experimental data did not exceed 3.6%.
Об авторах
A. Pavlyuchenko
State Research Center “Iceberg”
							Автор, ответственный за переписку.
							Email: andy_pavluchenko@ukr.net
				                					                																			                												                	Украина, 							Kyiv						
P. Loshitskiy
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”
														Email: andy_pavluchenko@ukr.net
				                					                																			                												                	Украина, 							Kyiv						
A. Shelengovskiy
State Research Center “Iceberg”
														Email: andy_pavluchenko@ukr.net
				                					                																			                												                	Украина, 							Kyiv						
V. Babenko
State Research Center “Iceberg”
														Email: andy_pavluchenko@ukr.net
				                					                																			                												                	Украина, 							Kyiv						
Дополнительные файлы
 
				
			 
						 
					 
						 
						 
						 
									 
  
  
  
  
  Отправить статью по E-mail
			Отправить статью по E-mail  Открытый доступ
		                                Открытый доступ Доступ предоставлен
						Доступ предоставлен Только для подписчиков