Clinical, Roentgenologic and Pododynamography Results of Minimum Invasive Total Hip Arthroplasty

Cover Page

Cite item

Full Text

Abstract

Clinical, roentgenologic and pododynamographic data were analyzed for 195 patients after 207 total hip arthroplasties performed via modified minimum invasive anteroexternal approach by Watson-Jones during the period from 2004 to 2006. Clinical results showed reduction of rehabilitation period and significant relief of postoperative pain syndrome. The rate of complications corresponded to that at conventional technique application. Despite slight varus position of the femoral component roentgenologic examination results were also comparable. Analysis of gait showed its considerable improvement and decrease in preoperative asymmetry between healthy and operated sides already in 4 months after operation. Residual differences were almost not observed in 6 months after intervention. Obtained clinical results confirmed the advantages of the applied technique.

About the authors

F. Laykher

Фридрих-Шиллер-Университет г. Йена, Германия

доктор техн. наук, инженер, клиника ортопедии Фридрих-Шиллер-Университета, Рудольф Элле больницы

K. Sandler

Фридрих-Шиллер-Университет г. Йена, Германия

доктор техн. наук, инженер, клиника ортопедии Фридрих-Шиллер-Университета, Рудольф Элле больница

S. Scheider

Рудольф Элле больница, г. Айзенберг, Германия

доктор медицины, врач клиники внутренних болезней, Рудольф Элле больница г. Айзенберг

J. Babisch

Фридрих-Шиллер-Университет г. Йена, Германия

доктор медицины, старший врач, кафедра ортопедии Фридрих-Шиллер- Университета

M. N Seleznyov

Фридрих-Шиллер-Университет г. Йена, Германия

врач, кафедра ортопедии Фридрих-Шиллер-Университета

A. B But-Gusaim

ГБОУ ВПО «Российский национальный исследовательский медицинский университет им. Н.И. Пирогова» Минздрасоцразвития России, Москва, РФ

доктор мед. наук, профессор клиники ортопедии РНИМУ

I. V Sirotin

ГБОУ ВПО «Российский национальный исследовательский медицинский университет им. Н.И. Пирогова» Минздрасоцразвития России, Москва, РФ

канд. мед. наук, врач клиники ортопедии РНИМУ

A. Anatol'evich Pimenov

ГБОУ ВПО «Российский национальный исследовательский медицинский университет им. Н.И. Пирогова» Минздрасоцразвития России, Москва, РФ

Email: pimenov-doctor@yandex.ru
врач клиники ортопедии РНИМУ; Тел.: 8 (916) 323-16-38. 119607, Москва, ул. Раменки, д.9, к.3, кв.443

A. Rot

Фридрих-Шиллер-Университет г. Йена, Германия

приват-доцент, старший врач, доктор медицины кафедры ортопедии Фридрих-Шиллер-Университета

References

  1. Roth A., Venbrocks R.A. Total hip replacement through a minimally invasive, anterolateral approach with the patient supine. Oper. Orthop. Traumatol. 2007;19 (5-6): 442-457.
  2. Roth A., Layher F., Venbrocks R.A. Transgluteale miniinzision - technik und eigene resultate. Orthopдde. 2006; 35 (7): 744-750.
  3. Watson-Jones R. Fractures of the neck of the femur. 1936; Br. Surg. 23: 787-808.
  4. Brooker A.F., Bowerman J.W., Robinson R.A., Riley L.H. Jr. Ectopic ossification following total hip replacement: incidence and method of classification. J. Bone Jt Surg. Am.1973; 55 (8): 1629-1632.
  5. Rittmeister M., Peters A. ^nstlicher ^ftgelenksersatz ьber eine posteriore Mini-Inzision - Ergebnisse in 76 aufeinanderfolgenden Fдllen. Z. Orthop. 2005;143 (4): 403-411.
  6. Higuchi F., Gotoh M., Yamaguchi N. Suzuki R., Kunou Y., Ooishi K., Nagata K. Minimally invasive uncemented total hip arthroplasty through an anterolateral approach with a shorter skin incision. J. Orthop. Sci. 2003; 8 (6): 812-817.
  7. Hozack W.J., Krismer M., Nogler M. Minimal invasive total joint arthroplasty. Berlin: Springer Heidelberg New York, 2004: S 11-16.
  8. WENS J.F., Gurkan I., Jibodh S.R. Mini-incision total hip arthroplasty: a comparative assessment of perioperative outcomes. Orthopedics. 2002; 25 (10): 10311043.
  9. Rachbauer F. Minimal-invasive ^ftendoprothetik ьber einen direkten vorderen Zugang. Orthopдde. 2005; 34 (11): 1103-1110.
  10. Goergen T.G., Resnick D. Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centring. Br. J. Radiol. 1975; 48 (568): 259-260.
  11. Lindgren J.U., Rysavy J. Restoration of femoral offset during hip replacement. Acta Orthop. Scand. 1992; 63 (4): 407-410.
  12. Schneider U., Breusch S.J., Thomsen M., Wirtz D.C., Lukoschek M. Einfluss der Implantatposition einer H^tendoprothese auf die Standzeit am Beispiel des CLS- Schaftes. Unfallchirurg. 2002; 105 (1): 31-35.
  13. Murray D.W. The definition and measurement of acetabular orientation. J. Bone Jt Surg. Br. 1993; 75 (2): 228-232.
  14. Lewinnek G.E., Lewis J.L., Tarr R., Compere C.L., Zimmermann J.R. Dislocation after total hip- replacement arthroplasties. J. Bone Joint Surg. Am. 1978; 60 (2): 217-220.
  15. Lembeck B., Mbiller O., Reize P., Wbdker N. Pelvic tilt makes acetabular cup navigation inaccurate. Acta Orthopaedica 2005; 76 (4): 517-523.
  16. Yang W.E., Shih C.H. Porous coated total hip arthroplasty: 5- to 10-year follow up. Changgeng Yi Xue Za Zhi. 1998; 21 (4): 397-402.
  17. Sander K., Roth A., Layher F., Babisch J., Erler K., Neumann U. Kurzzeitergebnisse nach HTEP- Implantation mit minimalinvasivem Zugang mod. n. Watson/Jones verifiziert mittels Ganganalyse. Orthopдdische Praxis. 2006; 42: 582-591.
  18. Perry J. Ganganalyse - Norm und Pathologie des Gehens., Mьnchen, Jena: Urban & Fischer; 2003.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2012 Eco-Vector



Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».