A Degenerate Birdcage with Integrated Tx/Rx Switches and Butler Matrix for the Human Limbs at 7 T
- Authors: Stara R.1,2,3, Tiberi G.4, Morsani F.2, Symms M.5, Fantacci M.E.1, Marletta M.6, Zampa V.6, Pendse M.3, Retico A.2, Rutt B.K.3, Tosetti M.4,7
- 
							Affiliations: 
							- Physics Department, University of Pisa
- Pisa Division, National Institute for Nuclear Physics (INFN)
- Department of Radiology, Stanford University
- IMAGO7 Foundation
- GE Applied Science Laboratory
- Department of Diagnostic and Interventional Radiology, Azienda Ospedaliero-Universitaria Pisana (AOUP)
- IRCCS Stella Maris Foundation
 
- Issue: Vol 48, No 3 (2017)
- Pages: 307-326
- Section: Original Paper
- URL: https://journal-vniispk.ru/0937-9347/article/view/247661
- DOI: https://doi.org/10.1007/s00723-017-0864-2
- ID: 247661
Cite item
Abstract
The theoretically known degeneracy condition of the band-pass birdcage coil has rarely been exploited in transmit coil designs. We have created an eight-channel degenerate birdcage for the human limbs at 7 T, with dedicated Tx/Rx switches and a Butler matrix. The coil can be split into two half cylinders, as required for its application to patients with limited mobility. The design of the coil, the Butler matrix, and Tx/Rx switches relied on a combination of analytical, circuital, and numerical simulations. The birdcage theory was extended to the degenerate case. The theoretical and practical aspects of the design and construction of the coil are presented. The performance of the coil was demonstrated by simulations, workbench, and scanner measurements. The fully assembled prototype presents good performance in terms of efficiency, B1 homogeneity, and signal-to-noise ratio, despite the asymmetry introduced by the splittable design. The first in vivo images of the knee are also shown. A novel RF coil design consisting of an eight-channel splittable degenerate birdcage has been developed, and it is now available for 7 T MRI applications of the human lower limbs, including high-resolution imaging of the knee cartilages and of the patellar trabecular structure.
About the authors
Riccardo Stara
Physics Department, University of Pisa; Pisa Division, National Institute for Nuclear Physics (INFN); Department of Radiology, Stanford University
							Author for correspondence.
							Email: rstara@stanford.edu
				                	ORCID iD: 0000-0002-9493-5645
				                																			                												                	Italy, 							Largo B. Pontecorvo 3, Pisa, 56127; Largo B. Pontecorvo 3, Pisa, 56127; 1201 Welch Road, Stanford, CA, 94305						
Gianluigi Tiberi
IMAGO7 Foundation
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Viale Del Tirreno 331, Calambrone, Pisa, 56018						
Fabio Morsani
Pisa Division, National Institute for Nuclear Physics (INFN)
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Largo B. Pontecorvo 3, Pisa, 56127						
Mark Symms
GE Applied Science Laboratory
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Viale del Tirreno 331, Calambrone, Pisa, 56018						
Maria Evelina Fantacci
Physics Department, University of Pisa
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Largo B. Pontecorvo 3, Pisa, 56127						
Massimo Marletta
Department of Diagnostic and Interventional Radiology, Azienda Ospedaliero-Universitaria Pisana (AOUP)
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Via Paradisa 2, Pisa, 56124						
Virna Zampa
Department of Diagnostic and Interventional Radiology, Azienda Ospedaliero-Universitaria Pisana (AOUP)
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Via Paradisa 2, Pisa, 56124						
Mihir Pendse
Department of Radiology, Stanford University
														Email: rstara@stanford.edu
				                					                																			                												                	United States, 							1201 Welch Road, Stanford, CA, 94305						
Alessandra Retico
Pisa Division, National Institute for Nuclear Physics (INFN)
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Largo B. Pontecorvo 3, Pisa, 56127						
Brian K. Rutt
Department of Radiology, Stanford University
														Email: rstara@stanford.edu
				                					                																			                												                	United States, 							1201 Welch Road, Stanford, CA, 94305						
Michela Tosetti
IMAGO7 Foundation; IRCCS Stella Maris Foundation
														Email: rstara@stanford.edu
				                					                																			                												                	Italy, 							Viale Del Tirreno 331, Calambrone, Pisa, 56018; Viale del Tirreno, 331, Calambrone, Pisa, 56018						
Supplementary files
 
				
			 
					 
						 
						 
						 
						 
				 
  
  
  
  
  Email this article
			Email this article  Open Access
		                                Open Access Access granted
						Access granted Subscription Access
		                                		                                        Subscription Access
		                                					