Symmetry of Arc Furnace Operation
- 作者: Shurygin Y.A.1
- 
							隶属关系: 
							- Lipetsk State Technical University
 
- 期: 卷 47, 编号 11 (2017)
- 页面: 732-736
- 栏目: Article
- URL: https://journal-vniispk.ru/0967-0912/article/view/179866
- DOI: https://doi.org/10.3103/S0967091217110110
- ID: 179866
如何引用文章
详细
The electrical asymmetry in the operation of arc furnace with an asymmetric triangular configuration of the electrodes is noted. Experimental data from the DSP-100 furnace permit analysis of how the electrical parameters affect the arc characteristics. Nonuniform power distribution over the phases of the electrofurnace decreases the component of the useful power consumed in heating the metal and slag. The power consumption by the furnace may potentially be reduced by 7.4% and the electrode consumption by 9%. The results confirm the need for research on phase-by-phase regulation of the power of ac arc furnaces.
作者简介
Yu. Shurygin
Lipetsk State Technical University
							编辑信件的主要联系方式.
							Email: shurygin_86@mail.ru
				                					                																			                												                	俄罗斯联邦, 							Lipetsk						
补充文件
 
				
			 
						 
						 
					 
						 
						 
				 
  
  
  
  
  电邮这篇文章
			电邮这篇文章  开放存取
		                                开放存取 ##reader.subscriptionAccessGranted##
						##reader.subscriptionAccessGranted## 订阅存取
		                                		                                        订阅存取
		                                					