TRANSDERMAL FENTANYL: PHARMACOLOGICAL ASPECTS OF THERAPY IN CANCER PATIENTS. PART 1. FROM THE DEVELOPMENT OF TRANSDERMAL FENTANYL FORMULATIONS TILL META-ANALYSES OF CLINICAL TRIALS


如何引用文章

全文:

详细

There was given a review of data on pharmacology of fentanyl with focus on transdermal formulation. In the first part of the article improvements in technology of fentanyl transdermal patches were reviewed and advantages of the membrane-matrix system that are of practical use were highlighted. The results obtained from bioequivalence and therapeutic equivalence studies of traditional and improved transdermal fentanyl systems were given. Clinical trials with fentanyl transdermal patches as well as systematic reviews and meta-analyses on the efficacy and safety of transdermal fentanyl were summarized. The second part of the article will focus on factors contributing to the variability in pharmacokinetics and pharmacodynamics of fentanyl including pharmacogenetics; the taking into account the whole spectrum of these factors would allow to escaped the majority of errors during the administration of the drug e.g. transdermally. A special attention will be paid to basic principles and issues of the application of fentanyl transdermal therapeutic systems.

作者简介

Aleksander Sidorov

Yaroslavl State Medical University

Email: alekssidorov@ya.ru
MD, PhD, DSc, Associate Professor of the Department of Pharmacology, Yaroslavl, 150000, Russian Federation Yaroslavl, 150000, Russian Federation

参考

  1. WHO. Cancer Pain Relief. 2nd Ed. 1996/
  2. Каприн А.Д., Абузарова Г.Р., Хороненко В.Э., Алексеева Г.С., Костин А.А., Старинский В.В., Алексеев Б.Я. Фармакотерапия хронического болевого синдрома у взрослых пациентов при оказании паллиативной помощи в стационарных и амбулаторно-поликлинических условиях: Методические рекомендации. М.: ФГБУ «МНИОИ им. П.А. Герцена»; 2015.
  3. Ripamonti C.I., Bandieri E., Roila F. On behalf of the ESMO Guidelines Working Group. Management of cancer pain: ESMO Clinical Practice Guidelines. Ann. Oncol. 2012;23 (Suppl. 7): vii139-54.
  4. Доклад Министра здравоохранения Российской Федерации В.И. Скворцовой на заседании итоговой Коллегии Минздрава России «Об итогах работы Министерства здравоохранения Российской Федерации в 2015 году и задачах на 2016 год».
  5. Абузарова Г.Р., Хороненко В.Э., Сарманаева Р.Р. Опиоидные анальгетики для терапии хронической боли у онкологических больных в России. История вопроса и перспективы. Анестезиол. и реаниматол. 2015;60(1):19-25.
  6. Фонарев М.Ю., Черкасов Д.И. Шершакова Л.В. Вопросы обеспечения адекватной опиоидной терапии при оказании паллиативной и других видов медицинской помощи. Вестник Росздравнадзора. 2015; (4): 48-52.
  7. Langford R., McKenna F., Ratcliffe S., Vojtassa´k J., Richarz U. Transdermal fentanyl for improvement of pain and functioning in osteoarthritis: a randomized, placebo-controlled trial. Arthr. and Rheum. 2006; 54: 1829-37.
  8. Simpson R.K. Jr., Edmondson E.A., Constant C.F., Collier C. Transdermal fentanyl as treatment for chronic low back pain. J. Pain Symptom Manage. 1997; 14: 218-24.
  9. Ohtori S., Inoue G., Orita S., Eguchi Y., Ochiai N., Kishida S. et al. Transdermal fentanyl for chronic low back pain. Yonsei Med. J. 2012; 53: 788-93.
  10. Pergolizzi J., Boger R., Budd K., Dahan A., Erdine S., Hans G. et al. Opioids and the management of chronic severe pain in the rlderly: Consensus statement of an international expert panel with focus on the six clinically most oftenused World Health Organization step III opioids (buprenorphine, fentanyl, hydromorphone, methadone, morphine, oxycodone). Pain Pract. 2008; 8(4): 287-313.
  11. Subedi R.K., Oh S.Y., Chun M.K., Choi H.K. Recent advances in transdermal drug delivery. Arch. Pharm Res. 2010; 33(3): 339-51.
  12. Mitragotri S. Breaking the skin barrier. Adv. Drug Deliv. Rev. 2004; 56: 555-6.
  13. Lane M.E. The transdermal delivery of fentanyl. Eur. J. Pharm. Biopharm. 2013; 84(3): 449-55.
  14. Potts R.O., Guy R.H. Predicting skin permeability. Pharm. Res. 1992; 9: 663-9.
  15. Prausnitz M.R., Langer R. Transdermal drug delivery. Nat. Biotechnol. 2008; 26: 1261-8.
  16. Choi H.-K., Flynn G.L., Amidon G.L. Transdermal delivery of bioactive peptides: The effect of n-decylmethyl sulfoxide, pH and inhibitors on encephalin transport. Pharm. Res. 1990; 7: 1099-106.
  17. Moffat A.C., Osselton M.D., Widdop B. (Eds.). Clarke’s Analysis of Drugs and Poisons, 3rd Ed. London: The Pharmaceutical Press; 2004: 1029-30.
  18. Roy S.D., Flynn G.L. Solubility behavior of narcotic analgesics in aqueous media: solubilities and dissociation constants of morphine, fentanyl, and sufentanil. Pharm. Res. 1989; 6: 147-51.
  19. Varvel J.R., Shafer S.L., Hwang S.S., Coen P.A., Stanski D.R. Absorbtion characteristics of transdermally administered fentanyl. Anesthesilogy. 1989; 43: 155-62.
  20. Roy S.D., Flynn G.L. Transdermal delivery of narcotic analgesics: comparative permeabilities of narcotic analgesics through human cadaver skin. Pharm. Res. 1989; 6: 825-32.
  21. Scott J.C., Cooke J.E., Stanski D.R. Electroencephalographic quantitation of opioid effect: comparative pharmacodynamics of fentanyl and sufentanil. Anesthesiology. 1991; 74(1): 34-42.
  22. Mather L.E. Clinical pharmacokinetics of fentanyl and its newer derivatives. Clin. Pharmacokinet. 1983; 8: 422-46.
  23. Leppert W. Pain management in patients with cancer: focus on opioid analgesics. Curr. Pain Headache Rep. 2011; 15: 271-9.
  24. Инструкция по медицинскому применению ТТС бупренорфина (Транстек®).
  25. Инструкция по медицинскому применению ТТС фентанила (Фендивия®).
  26. Roy S.D., Gutierrez M., Flynn G.L., Cleary G.W. Controlled transdermal delivery of fentanyl: characterizations of pressure-sensitive adhesives for matrix patch design. J. Pharm. Sci. 1996; 85: 491-5.
  27. Kress H.G., Boss H., Delvin T., Lahu G., Lophaven S., Marx M. et al. Transdermal fentanyl matrix patches Matrifen and Durogesic DTrans are bioequvivalent. Eur. J. Pharm. Biopharm. 2010; 75: 225-31.
  28. Marier J.F., Lor M., Potvin D., Dimarco M., Morelli G., Saedder E.A. Pharmacokinetics, tolerability, and performance of a novel matrix transdermal delivery system of fentanyl relative to the commercially available reservoir formulation in healthy subjects. J. Clin. Pharmacol. 2006; 46: 642-53.
  29. Marier J.F. Comparative bioequivalence study between a novel matrix transdermal delivery system of fentanyl and a commercially available reservoir formulation. Br. J. Clin. Pharmacol. 2007; 63: 121-4.
  30. Kress H.G., Von der Laage D., Hoerauf K.H., Nolte T., Heiskanen T., Petersen R. et al. A randomized, open, parallel group, multicenter trial to investigate analgesic efficacy and safety of a new transdermal fentanyl patch compared to standard opioid treatment in cancer pain. J. Pain Symptom Manage. 2008; 36(3): 268-79.
  31. van Seventer R., Smit J.M., Schipper R.M., Wicks M.A., Zuurmond W.W. Comparison of TTS-fentanyl with sustained-release oral morphine in the treatment of patients not using opioids for mild-to-moderate pain. Curr. Med. Res. Opin. 2003; 19(6): 457-69.
  32. Oztürk T., Karadibak K., Catal D., Çakan A., Tugsavul F., Çırak K. Comparison of TD-fentanyl with sustained-release morphine in the pain treatment of patients with lung cancer. Agri. 2008; 20(3): 20-5.
  33. Mercadante S., Porzio G., Ferrera P., Fulfaro F., Aielli F., Verna L. et al. Sustained-release oral morphine versus transdermal fentanyl and oral methadone in cancer pain management. Eur. J. Pain. 2008; 12: 1040-6.
  34. Clark A.J., Ahmedzai S.H., Allan L.G., Camacho F., Horbay G.L., Richarz U., Simpson K. Efficacy and safety of transdermal fentanyl and sustained-release oral morphine in patients with cancer and chronic non-cancer pain. Curr. Med. Res. Opin. 2004; 20(9): 1419-28.
  35. Yang Q., Xie D.R., Jiang Z.M., Ma W., Zhang Y.D., Bi Z.F., Chen D.L. Efficacy and adverse effects of transdermal fentanyl and sustained-release oral morphine in treating moderate-severe cancer pain in Chinese population: a systematic review and meta-analysis. J. Exp. Clin. Cancer Res. 2010; 29: 67.
  36. Koyyalagunta D., Bruera E., Solanki D.R., Nouri K.H., Burton A.W., Toro M.P. et al. A systematic review of randomized trials on the effectiveness of opioids for cancer pain. Pain Physician. 2012; 15: ES39-58.
  37. Hadley G., Derry S., Moore R.A., Wiffen P.J. Transdermal fentanyl for cancer pain. Cochrane Database Syst. Rev. 2013; (10): CD010270.

补充文件

附件文件
动作
1. JATS XML

版权所有 © Eco-Vector, 2017


 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».