Absorption-Spectral Photometric Method of Measuring the Boric Acid Concentration in First-Loop Coolant of a Nuclear Power Reactor
- Autores: Mankevich S.K.1, Orlov E.P.2
-
Afiliações:
- Astrofizika Scientific and Production Association
- Lebedev Physical Institute, Russian Academy of Sciences (LPI RAS)
- Edição: Volume 121, Nº 5 (2017)
- Páginas: 339-343
- Seção: Article
- URL: https://journal-vniispk.ru/1063-4258/article/view/248275
- DOI: https://doi.org/10.1007/s10512-017-0208-1
- ID: 248275
Citar
Resumo
A modification of the absorption-spectral photometric method and a system based on it are proposed for measuring boric acid concentrations from 0.01 mg/liter to 10 g/liter or more to within 0.01 mg/liter directly in cooling loop of a water moderated and cooled power reactor. Compared with other systems, the method permits increasing the sensitivity and accuracy of boric acid concentration measurements 1000-fold and monitoring the concentration remotely at a radiation-safe distance.