Determination of the Heat-Exchange Characteristics of Low-Pressure Heat-Exchangers for Lead and Lead-Bismuth Cooled Loops


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Heat removal during transient processes in nuclear power installations and bench loops cooled by lead and lead-bismuth coolant is studied. It is shown that low-pressure heat-exchange equipment is effective. The studies were conducted in a non-isothermal loop with circulating of lead coolant at 450–500°C, average speed in the narrow section of the gap in longitudinal flow over the heat-exchange surface 0.1–1.05 m/sec, Peclet number 300–3300, and the oxygen thermodynamic activity in lead 1–10–3. The processes occurring in a non-isothermal liquid-metal loop with an experimental heat-exchange section model the dependence of the heat-exchange characteristics on impurity mass transfer in the loop.

作者简介

A. Beznosov

Nizhnii Novgorod State Technical University (NGTU)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Nizhnii Novgorod

A. Chernysh

Nizhnii Novgorod State Technical University (NGTU)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Nizhnii Novgorod

A. Zudin

Nizhnii Novgorod State Technical University (NGTU)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Nizhnii Novgorod

T. Bokova

Nizhnii Novgorod State Technical University (NGTU)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Nizhnii Novgorod

E. Novinskii

Afrikantov Experimental Design Bureau of Mechanical Engineering (OKBM Afrikantov)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Nizhnii Novgorod

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media New York, 2017