A system for monitoring the radiation effects of a proton linear accelerator
- Authors: Skorkin V.M.1, Belyanski K.L.1, Skorkin A.V.1
-
Affiliations:
- Institute for Nuclear Research
- Issue: Vol 79, No 9-10 (2016)
- Pages: 1410-1413
- Section: Charged Particle Accelerators for Nuclear Technologies
- URL: https://journal-vniispk.ru/1063-7788/article/view/191138
- DOI: https://doi.org/10.1134/S106377881609012X
- ID: 191138
Cite item
Abstract
The system for real-time monitoring of radioactivity of a high-current proton linear accelerator detects secondary neutron emission from proton beam losses in transport channels and measures the activity of radionuclides in gas and aerosol emissions and the radiation background in the environment affected by a linear accelerator. The data provided by gamma, beta, and neutron detectors are transferred over a computer network to the central server. The system allows one to monitor proton beam losses, the activity of gas and aerosol emissions, and the radiation emission level of a linear accelerator in operation.
About the authors
V. M. Skorkin
Institute for Nuclear Research
Author for correspondence.
Email: skorkin@inr.ru
Russian Federation, pr. 60-letiya Oktyabrya 7a, Moscow, 117312
K. L. Belyanski
Institute for Nuclear Research
Email: skorkin@inr.ru
Russian Federation, pr. 60-letiya Oktyabrya 7a, Moscow, 117312
A. V. Skorkin
Institute for Nuclear Research
Email: skorkin@inr.ru
Russian Federation, pr. 60-letiya Oktyabrya 7a, Moscow, 117312
Supplementary files