Stability of Natural Circulation in a Vertical Boiler-Utilizer Loop with Horizontal Evaporator Pipes During Startup


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Theoretical studies and field tests of the stability of natural circulation in the pipes of the horizontal evaporator of the PK-55 boiler-utilizer at the South-west Heat and Electric Power Plant (Yugo-zapadnaya TÉTs) are discussed. The experiments cover the stages of evaporator heating, onset of steam production, and stable natural circulation. During these studies the gas turbine was started and then held at a load of 5 MW. It is concluded that the evaporator with horizontal boiler-utilizer piping built for operation with repeated forced circulation can operate reliably for long periods in a natural circulation regime.

作者简介

K. Pleshanov

JSC Machine-Building Factory of Podolsk (ZIO); National Research University “Moscow Power Engineering Institute”

Email: sterkhovkv@gmail.com
俄罗斯联邦, Podolsk, Moscow oblast’; Moscow

K. Sterkhov

JSC Machine-Building Factory of Podolsk (ZIO)

编辑信件的主要联系方式.
Email: sterkhovkv@gmail.com
俄罗斯联邦, Podolsk, Moscow oblast’

P. Roslyakov

National Research University “Moscow Power Engineering Institute”

Email: sterkhovkv@gmail.com
俄罗斯联邦, Moscow