Steel-Reinforced Concrete Penstock Experiments
- Autores: Nikolaev V.B.1, Lisichkin S.E.2, Rubin O.D.3, Lisichkin A.S.2
-
Afiliações:
- JSC “Atoménergoproekt”
- Engineering Center for Structures and Technologies in Power Industry (ITs SKTE)
- Scientific-Research Institute of Energy Structures (NIIES)
- Edição: Volume 50, Nº 5 (2017)
- Páginas: 466-472
- Seção: Article
- URL: https://journal-vniispk.ru/1570-145X/article/view/245389
- DOI: https://doi.org/10.1007/s10749-017-0734-y
- ID: 245389
Citar
Resumo
Experimental results on steel-reinforced concrete penstocks with different ratios between the cross-sectional areas of the inner steel lining and the hoop reinforcement are presented. The formulas for the strength analysis of steel-reinforced concrete penstocks are improved to, in particular, take into account failure of the bond of the steel lining and reinforcement to concrete.
Sobre autores
V. Nikolaev
JSC “Atoménergoproekt”
Autor responsável pela correspondência
Email: valernik@inbox.ru
Rússia, Moscow
S. Lisichkin
Engineering Center for Structures and Technologies in Power Industry (ITs SKTE)
Email: valernik@inbox.ru
Rússia, Moscow
O. Rubin
Scientific-Research Institute of Energy Structures (NIIES)
Email: valernik@inbox.ru
Rússia, Moscow
A. Lisichkin
Engineering Center for Structures and Technologies in Power Industry (ITs SKTE)
Email: valernik@inbox.ru
Rússia, Moscow
Arquivos suplementares