Combination of neuromuscular block monitoring and hand grip strength assessment for patients undergoing emergency abdominal surgery

Cover Page

Cite item

Full Text

Abstract

Relevance. The hand grip strength measurement together with neuromuscular block monitoring played an important role during surgery. They both helped in losing less time during surgery and also facilitate the task of the surgeon. The aim of this study was to reduce time on intubation, facilitate the task of the surgeon and to limit post-surgical pain. In rehabilitation, hand grip strength helps in determining further recuperation measures after a surgery. There are three fundamental principles for an anesthesiologist to ensure that the patient after combined endotracheal anesthesia can be extubated, the first one is to ask the patient to move his head forward, the second one is to ask the patient whether the intubation tube is disturbing him in his mouth and the third most important one is to make the patient hold his wrist very firmly. Materials and Methods. Monitoring of muscle relaxant on induction, intra and post-surgery is carried out using a TOF Watch SX in coordination with handgrip strength measurement on 46 patients aged from 18 to 60 years of BMI of 18-30 kg/m² 15min before endotracheal intubation and 15min, 45min and 210min post extubation by using a dynamometer “MEGEON 34090” to help us understand whether after extubation muscle strength changes and to what extent. Also, pre-anesthesiology protocol, combined endotracheal protocol, Microsoft excel advanced, monitoring of hemodynamics, ECG, PEEP, PCO2, PO2, respiratory volume using Drager Fabius. Results and Discussion. The results showed that to reach deep muscle relaxation both atracurium benzilate (FKP Kursk Biofabric company, Kursk, Russia) at TOF 0 took 258.5 ±  83.5 secs and Cisatracurium benzilate (ZAO Obninsk Chemical pharmaceutical company, Obninsk, Russia) at TOF0-252.4 ± 100.1 secs in emergency patients and basically hand grip strength also was lesser as compared to planned cholecystectomy patients. Conclusion. Rehabilitation was necessary for patients undergoing massive abdominal emergency surgeries underlying the fact that on a pain scale 10/10 post surgery, further treatments should be implemented to reduce pain, reduce residual neuromuscular block and muscle weakness after extubation at TOF 90-95%.

About the authors

Neelam Dhunputh

RUDN University

Author for correspondence.
Email: dhunputhneelam@gmail.com
ORCID iD: 0009-0004-7058-5021
Moscow, Russian Federation

Marina V. Petrova

RUDN University

Email: dhunputhneelam@gmail.com
ORCID iD: 0000-0003-4272-0957
Moscow, Russian Federation

Victor V. Moroz

RUDN University

Email: dhunputhneelam@gmail.com
ORCID iD: 0000-0002-3467-7170
Moscow, Russian Federation

Andrey V. Butrov

RUDN University

Email: dhunputhneelam@gmail.com
ORCID iD: 0000-0003-4462-1530
Moscow, Russian Federation

Marat F. Magomedov

RUDN University

Email: dhunputhneelam@gmail.com
ORCID iD: 0000-0002-1972-7336
Moscow, Russian Federation

References

  1. Chandrasekaran B, Ghosh A, Prasad C, Krishnan K, Chandrasharma B. Age and anthropometric traits predict handgrip strength in healthy normals. J Hand Microsurg. 2010;2(2):58-61. doi: 10.1007/s12593-010-0015-6
  2. Flood A, Chung A, Parker H, Kearns V, O’Sullivan TA. The use of hand grip strength as a predictor of nutrition status in hospital patients. Clin Nutr. 2014;33(1):106-114. doi: 10.1016/j.clnu.2013.03.003
  3. Huang DD, Yu DY, Wang WB. Global leadership initiative in malnutrition (GLIM) criteria using hand-grip strength adequately predicts postoperative complications and long-term survival in patients underwent radical gastrectomy for gastric cancer. Eur J Clin Nutr. 2022;76(9):1323-1331. doi: 10.1038/s41430-022-01109-2
  4. Yin L, Lin X, Zhao Z, Li N, He X, Zhang M, Yang J, Guo Z, Li Z, Wang K, Weng M, Cong M, Li S, Li T, Ma H, Ba Y, Li W, Cui J, Liu J, Song C, Shi H, Xu H. Is hand grip strength a necessary supportive index in the phenotypic criteria of the GLIM-based diagnosis of malnutrition in patients with cancer? Support Care Cancer. 2021;29(7):4001-4013. doi: 10.1007/s00520-020-05975-z
  5. Luna-­Heredia E, Martín-­Peña G, Ruiz-­Galiana J. Handgrip dynamometry in healthy adults. Clin Nutr. 2005;24(2):250-258. doi: 10.1016/j.clnu.2004.10.007
  6. Broens SJL, Boon M, Martini CH, Niesters M, Velzen MV, Aarts LPHJ, Dahan A. Reversal of Partial Neuromuscular Block and the Ventilatory Response to Hypoxia: A Randomized Controlled Trial in Healthy Volunteers. Anesthesiology. 2019;131(3):467-476. doi: 10.1097/ALN.0000000000002711
  7. Keevil VL, Luben R, Dalzell N, Hayaat S, Sayer AA, Wareham NJ, Khaw KT. Cross-sectional associations between different measures of obesity and muscle strength in men and women in a British cohort study. J Nutr Health Aging. 2015;19(1):3-11. doi: 10.1007/s12603-014-0492-6
  8. Krishna Prasad CR, Pratyusha AC, Sharmila C, Durga P, Sowjanya K, Harika K. Dynamometer based hand grip strength as a clinical tool for objective assessment of post-operative residual muscle weakness. Indian J Anaesth. 2022;66(10):707-711. doi: 10.4103/ija.ija_442_22
  9. Hermans G, Van den Berghe G. Clinical review: intensive care unit acquired weakness. Crit Care. 2015;19(1):274. Published 2015 Aug 5. doi: 10.1186/s13054-015-0993-7
  10. Latronico N, Bolton CF. Critical illness polyneuropathy and myopathy: a major cause of muscle weakness and paralysis. Lancet Neurol. 2011 Oct;10(10):931-41. doi: 10.1016/S1474-4422(11)70178-8.
  11. Stevens RD, Marshall SA, Cornblath DR, Hoke A, Needham DM, Jonghe BD, Ali NA, Sharshar T. A framework for diagnosing and classifying intensive care unit-acquired weakness. Crit Cre Med. 2009;37(10 Suppl): S299-S308. doi: 10.1097/CCM.0b013e3181b6ef67
  12. De Jonghe B, Bastuji-­Garin S, Sharshar T, Outin H, Brochard L. Does ICU-acquired paresis lengthen weaning from mechanical ventilation? Intensive Care Med. 2004;30(6):1117-1121. doi: 10.1007/s00134-004-2174-z
  13. Norman K, Stobäus N, Gonzalez MC, Schulzke JD, Pirlich M. Hand grip strength: outcome predictor and marker of nutritional status. Clin Nutr. 2011;30(2):135-142. doi: 10.1016/j.clnu.2010.09.010
  14. Stenholm S, Tiainen K, Rantanen T, Sainio P, Heliovaara M, Impivaara O, Koskinen S. Long-term determinants of muscle strength decline: prospective evidence from the 22-year mini-­Finland follow-up survey. J Am Geriatr Soc. 2012;60(1):77-85. doi: 10.1111/j.1532-5415.2011.03779.x
  15. Tzanis G, Vasileiadis I, Zervakis D, Karatzanos E, Dimopoulos S, Pitsolis T, Tripodaki E, Gerovasili V, Routsi C, Nanas S. Maximum inspiratory pressure, a surrogate parameter for the assessment of ICU-acquired weakness. BMC Anesthesiol. 2011;11:14. Published 2011 Jun 26. doi: 10.1186/1471-2253-11-14
  16. Samuel D, Rowe P. An investigation of the association between grip strength and hip and knee joint moments in older adults. Arch Gerontol Geriatr. 2012;54(2):357-360. doi: 10.1016/j.archger.2011.03.009
  17. Levine S, Nguyen T, Taylor N, Friscia ME, Budak MT, Rothenberg P, Zhu J, Sachdeva R, Sonnad S, Kaiser LR, Rubinstein NA, Powers SK, Shrager JB. Rapid disuse atrophy of diaphragm fibers in mechanically ventilated humans. N Engl J Med. 2008;358(13):1327-1335. doi: 10.1056/NEJMoa070447
  18. Ali NA, O’Brien JM Jr, Hoffmann SP, Phillips G, Garland A, Finley JCW, Almoosa K, Hejal R, Wolf KM, Lemeshow S, Jr AFC, Marsh CB; Consortium MCC. Acquired weakness, handgrip strength, and mortality in critically ill patients. Am J Respir Crit Care Med. 2008;178(3):261-268. doi: 10.1164/rccm.200712-1829OC
  19. Cottereau G, Dres M, Avenel A, Fichet J, Jacobs FM, Prat D, Hamzaoui O, Richard C, Antonello M, Sztrymf B. Handgrip Strength Predicts Difficult Weaning but Not Extubation Failure in Mechanically Ventilated Subjects. Respir Care. 2015;60(8):1097-1104. doi: 10.4187/respcare.03604
  20. Leyk D, Gorges W, Ridder D, Wunderlich M, Ruther T, Sievert A, Essfeld D. Hand-grip strength of young men, women and highly trained female athletes. Eur J Appl Physiol. 2007;99(4):415-421. doi: 10.1007/s00421-006-0351-1

Supplementary files

Supplementary Files
Action
1. JATS XML

Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».