The evaluation of heat capacity and choice of materials for short-term storage of diurnal solar heat surplus in passive solar heating systems
- Authors: Avezov R.R.1, Abdukhamidov D.U.1, Kuralov M.A.2, Rakhimov E.Y.1, Imomov S.B.3
-
Affiliations:
- Institute of Physics and Technology NPO
- International Solar Energy Institute
- Karshi Engineering Economic Institute
- Issue: Vol 52, No 4 (2016)
- Pages: 305-308
- Section: Solar Heat. Cold Supply and Accumulation Storage
- URL: https://journal-vniispk.ru/0003-701X/article/view/149228
- DOI: https://doi.org/10.3103/S0003701X16040058
- ID: 149228
Cite item
Abstract
The results of numerical studies aimed to evaluate the heat capacity of short-term phase change heat accumulators applied in passive solar heating systems (PSHS) with a three-layer energy active translucent enclosure (TE) are presented. An example is given of calculation of specific (per unit of TE surface area) weight of heat accumulator using dimethyl sulfoxide, (СН3)2SO, with melting temperature 18.6°C and latent heat of phase transition 173 kJ/kg, as the heat storage agent.
About the authors
R. R. Avezov
Institute of Physics and Technology NPO
Author for correspondence.
Email: avezov@uzsci.net
Uzbekistan, Tashkent
D. U. Abdukhamidov
Institute of Physics and Technology NPO
Email: avezov@uzsci.net
Uzbekistan, Tashkent
M. A. Kuralov
International Solar Energy Institute
Email: avezov@uzsci.net
Uzbekistan, Tashkent
E. Yu. Rakhimov
Institute of Physics and Technology NPO
Email: avezov@uzsci.net
Uzbekistan, Tashkent
Sh. B. Imomov
Karshi Engineering Economic Institute
Email: avezov@uzsci.net
Uzbekistan, Karshi
Supplementary files