Orientation of heated premise in the design of insolation passive heating systems
- Authors: Avezova N.R.1,2, Rakhimov E.Y.1
-
Affiliations:
- International Solar Energy Institute
- Physical–Technical Institute, Physics–Sun Scientific Association
- Issue: Vol 53, No 4 (2017)
- Pages: 338-343
- Section: Solar Heat. Cold Supply, And Accumulation Storage
- URL: https://journal-vniispk.ru/0003-701X/article/view/149356
- DOI: https://doi.org/10.3103/S0003701X17040053
- ID: 149356
Cite item
Abstract
The technique for calculating the start and end times and the direct sunlight illumination period is described. The cumulative solar radiation (SR) falling on the front surface of translucent enclosures (TE) of heated premise (HP) is found. The final design results are based on processing 4-year generalized data from the Parkent weather station.
About the authors
N. R. Avezova
International Solar Energy Institute; Physical–Technical Institute, Physics–Sun Scientific Association
Author for correspondence.
Email: avezov@uzsci.net
Uzbekistan, Tashkent, 100084; Tashkent, 100084
E. Yu. Rakhimov
International Solar Energy Institute
Email: avezov@uzsci.net
Uzbekistan, Tashkent, 100084
Supplementary files