Analysis of the Efficiency of a Pd/Ag Membrane with a Thickness of 2.25 Microns on a Porous Ceramic Substrate in a Laboratory Membrane Reactor


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The main parameters of a laboratory membrane reactor for methane-steam reforming were analyzed by mathematical modeling. The high efficiency of a Pd/Ag membrane with a thickness of 2.25 microns on a porous ceramic substrate was confirmed by estimating the average hydrogen diffusion flow density to be 90−120 m3H2/(m2·hr).

About the authors

A. B. Vandyshev

Institute of Engineering Science, Ural Branch of the Russian Academy of Sciences (UB RAS)

Author for correspondence.
Email: vandyshev@imach.uran.ru
Russian Federation, Ekaterinburg

V. A. Kulikov

Institute of Engineering Science, Ural Branch of the Russian Academy of Sciences (UB RAS)

Email: vandyshev@imach.uran.ru
Russian Federation, Ekaterinburg