Сalculation of Concentration Polarization in Electromembrane Devices with Spiral Wound Modules
- Authors: Abonosimov O.A.1, Lazarev S.I.1, Kotenev S.I.1, Khokhlov P.A.1
-
Affiliations:
- Tambov State Technical University
- Issue: Vol 55, No 3-4 (2019)
- Pages: 197-203
- Section: Article
- URL: https://journal-vniispk.ru/0009-2355/article/view/236527
- DOI: https://doi.org/10.1007/s10556-019-00605-w
- ID: 236527
Cite item
Abstract
The article presents the results of calculating the concentration polarization values for electric baromembrane separation of electroplating wastewater based on solving the Nernst–Planck and Poisson–Boltzmann equations with determining the concentration field along the length and height of the intermembrane channel. The dependence of concentration polarization on the solution flow rate, transmembrane pressure, temperature and concentration was analyzed.
About the authors
O. A. Abonosimov
Tambov State Technical University
Author for correspondence.
Email: geometry@mail.nnn.tstu.ru
Russian Federation, Tambov
S. I. Lazarev
Tambov State Technical University
Email: geometry@mail.nnn.tstu.ru
Russian Federation, Tambov
S. I. Kotenev
Tambov State Technical University
Email: geometry@mail.nnn.tstu.ru
Russian Federation, Tambov
P. A. Khokhlov
Tambov State Technical University
Email: geometry@mail.nnn.tstu.ru
Russian Federation, Tambov
Supplementary files