Effect of the Architecture on Energy Efficiency of Electric Arc Furnaces of Conventional and Consteel Designs
- Autores: Makarov A.N.1
-
Afiliações:
- Federal State Budgetary Educational Institution of Higher Education “Tver State Technical University”
- Edição: Volume 62, Nº 9-10 (2019)
- Páginas: 882-891
- Seção: Article
- URL: https://journal-vniispk.ru/0026-0894/article/view/242366
- DOI: https://doi.org/10.1007/s11015-019-00743-9
- ID: 242366
Citar
Resumo
Heat transfer and arc efficiency of the electric arc furnaces (EAF) of Consteel (DSP-120co) and conventional (DSP-120ob) designs, equipped with the modern melting process intensification means, have been analyzed. For comparison purposes, EAFs of similar capacity and performance were used. As a result of analysis, it was found that the average arc efficiency of the Consteel DSP-120co furnace is 8 to 9% lower than that of the DSP-120ob furnace. The analysis of the EAF arc efficiency made it possible to explain the higher specific energy consumption by the DSP-120co compared to that of the DSP-120ob furnace.
Palavras-chave
Sobre autores
A. Makarov
Federal State Budgetary Educational Institution of Higher Education “Tver State Technical University”
Autor responsável pela correspondência
Email: tgtu_kafedra_ese@mail.ru
Rússia, Tver
Arquivos suplementares