Effect of the Architecture on Energy Efficiency of Electric Arc Furnaces of Conventional and Consteel Designs


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Heat transfer and arc efficiency of the electric arc furnaces (EAF) of Consteel (DSP-120co) and conventional (DSP-120ob) designs, equipped with the modern melting process intensification means, have been analyzed. For comparison purposes, EAFs of similar capacity and performance were used. As a result of analysis, it was found that the average arc efficiency of the Consteel DSP-120co furnace is 8 to 9% lower than that of the DSP-120ob furnace. The analysis of the EAF arc efficiency made it possible to explain the higher specific energy consumption by the DSP-120co compared to that of the DSP-120ob furnace.

作者简介

A. Makarov

Federal State Budgetary Educational Institution of Higher Education “Tver State Technical University”

编辑信件的主要联系方式.
Email: tgtu_kafedra_ese@mail.ru
俄罗斯联邦, Tver

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, part of Springer Nature, 2019