Using the Talbot Effect for Summation of Microwave Signals in the Millimeter-Wavelength Band
- Autores: Denisov G.G.1,2, Shmelyov M.Y.1
-
Afiliações:
- Institute of Applied Physics of the Russian Academy of Sciences
- N. I. Lobachevsky State University of Nizhny Novgorod
- Edição: Volume 58, Nº 10 (2016)
- Páginas: 789-792
- Seção: Article
- URL: https://journal-vniispk.ru/0033-8443/article/view/243642
- DOI: https://doi.org/10.1007/s11141-016-9651-4
- ID: 243642
Citar
Resumo
We consider the problem of summing the power produced by several coherent sources of microwaves and propose to use the Talbot effect in an oversized rectangular waveguide to solve it. The operating frequency of the summator is 94.4 GHz. The calculated coefficient of summation of individual signals is equal to 2.8 dB in the 800 MHz frequency range with allowance for the ohmic loss. Computer simulation of the summator has been performed, and its characteristics have been studied at a low power level.
Palavras-chave
Sobre autores
G. Denisov
Institute of Applied Physics of the Russian Academy of Sciences; N. I. Lobachevsky State University of Nizhny Novgorod
Email: shm@appl.sci-nnov.ru
Rússia, Nizhny Novgorod; Nizhny Novgorod
M. Shmelyov
Institute of Applied Physics of the Russian Academy of Sciences
Autor responsável pela correspondência
Email: shm@appl.sci-nnov.ru
Rússia, Nizhny Novgorod
Arquivos suplementares