Characteristics of electric arc furnaces powered by a low-frequency alternating current
- Authors: Mironov Y.M.1, Mironova A.N.1
- 
							Affiliations: 
							- Chuvash State University
 
- Issue: Vol 2016, No 6 (2016)
- Pages: 485-489
- Section: Simulation of Metallurgical and Thermal Processes
- URL: https://journal-vniispk.ru/0036-0295/article/view/170594
- DOI: https://doi.org/10.1134/S0036029516060112
- ID: 170594
Cite item
Abstract
The changes in the parameters of a DSP-100 electric arc furnace that are induced by a decrease in the current frequency are considered. It is shown that the related decrease in the current lead resistances causes an increase in the arc power and voltage, a decrease in the reactive power, and an increase in the electrical efficiency and the power coefficient. The heat indices are expected to be significantly improved.
About the authors
Yu. M. Mironov
Chuvash State University
							Author for correspondence.
							Email: mironovu@mail.ru
				                					                																			                												                	Russian Federation, 							Moskovskii pr. 15, Cheboksary, 428015						
A. N. Mironova
Chuvash State University
														Email: mironovu@mail.ru
				                					                																			                												                	Russian Federation, 							Moskovskii pr. 15, Cheboksary, 428015						