Influence of thermal hysteresis on distortions of zero line at various comparator type equivalent time signal conversion methods
- Authors: Krumin’sh K.1, Peterson V.1, Plotsin’sh V.1
-
Affiliations:
- Institute of Electronics and Computer Science
- Issue: Vol 50, No 1 (2016)
- Pages: 20-27
- Section: Article
- URL: https://journal-vniispk.ru/0146-4116/article/view/174337
- DOI: https://doi.org/10.3103/S0146411616010053
- ID: 174337
Cite item
Abstract
The influence of thermal hysteresis of the comparator on the sensitivity of signal converter and distortions of the zero line at various comparator type equivalent time signal conversion methods is studied. The research is carried out by statistical simulations and physical experiments. In the simulations two sets of parameters of the thermal hysteresis are used: one appropriate to parameters of experimental device, and the second—appropriate to comparator with a stronger thermal hysteresis.
About the authors
K. Krumin’sh
Institute of Electronics and Computer Science
Author for correspondence.
Email: krumins@edi.lv
Latvia, Dzerbenes Str.14, Riga, LV-1006
V. Peterson
Institute of Electronics and Computer Science
Email: krumins@edi.lv
Latvia, Dzerbenes Str.14, Riga, LV-1006
V. Plotsin’sh
Institute of Electronics and Computer Science
Email: krumins@edi.lv
Latvia, Dzerbenes Str.14, Riga, LV-1006
Supplementary files