The rationale application of donor material: original ten years experience, possible ways of development and literature data


Cite item

Full Text

Abstract

Lately, layer-wise keratoplasty became the first operation of choice in case of pathology of cornea. In view of satisfying results of endothelial surgery similar operations are implemented at earlier stages that increases need in donor tissue. With increasing of life span of population, also increases number of patients in need of transplantation of cornea. The number of intact cadaver cornea decreases because of stable increase of surgical interventions on front segment of eye. The present article presents original ten years experience concerning optimization of application of donor tissue and indicate on possibilities of further increasing of number of applied keratoplasties. From 2009 to 2015 in the Helmholtz Moscow research institute of eyes diseases 652 transplantations of cornea were implemented in various modifications: straight-through keratoplasty, transplantation of Descemet's membrane with endothelium (DMEK), deep front layer-wise keratoplasty, endokeratoplasty (DSEK) with various modes of transplant formation and 23 frontal layer-wise keratoplasties. In transplantation were also used eyes of donors with radial keratotomy, after laser keratomileusis and with artificial intra-ocular lens. To implement 652 operations 528 cadaver eyes with average age 41 ± 32,5 years (varying from 21 to 87 years) were required. The number of transplantations increased approximately on 50% at potential up to 75%. The lamellar surgery permits using corneal donor tissue with altered frontal surface and to increase number of transplantations of cornea. The renunciation of application of corneal donor tissue with altered frontal surface is inexpedient.

About the authors

Oganes G. Oganesyan

The Helmholtz Moscow research institute of eyes diseases

Email: oftalmolog@mail.ru
doctor of medical sciences, senior researcher of department of traumatology and reconstructive surgery 105062, Moscow, Russia

S. S Yakovleva

The Helmholtz Moscow research institute of eyes diseases

105062, Moscow, Russia

M. P Kharlampidi

The Helmholtz Moscow research institute of eyes diseases

105062, Moscow, Russia

A. A Grdikanyan

The Helmholtz Moscow research institute of eyes diseases

105062, Moscow, Russia

References

  1. Phillips P., Terry M., Shamie N., Chen E., Hoar K., Stoeger C. et al. Descemet’s stripping automated endothelial keratoplasty (DSAEK) using corneal donor tissue not acceptable for use in penetrating keratoplasty as a result of anterior stromal scars, pterygia, and previous corneal refractive surgical procedures. Cornea. 2009; 28(8): 871-6.
  2. Priglinger S., Neubauer A., May C., Alge C., Wolf A., Mueller A. et al. Optical coherence tomography for the detection of laser in situ keratomileusis in donor corneas. Cornea. 2003; 22(1): 46-50.
  3. Vajpayee R.B., Sharma N., Jhanji V., Titiyal J., Tandon R. One donor cornea for 3 recipients: a new concept for corneal transplantation surgery. Arch. Ophthalmol. 2007; 125(4): 552-4.
  4. Sharma N., Agarwal P., Titiyal J., Kumar C., Sinha R., Vajpayee R. Optimal use of donor corneal tissue: one cornea for two recipients. Cornea. 2011; 30(10): 1140-4.
  5. Armour R., Ousley P., Wall J., Hoar K., Stoeger C., Terry M. Endothelial keratoplasty using donor tissue not suitable for full-thickness penetrating keratoplasty. Cornea. 2007; 26(5): 515-9.
  6. Davis D., Karth P., Croasdale C., Koenig S. Tears of post-LASIK corneal donor tissue during surgeon-performed donor graft preparation for DSAEK. Invest. Ophthalmol. Vis. Sci. 2013; 54(15): 3088.
  7. Moshirfar M., Khalifa Y., Davis D., Fenzl C., Espandar L., Chang A. et al. Descemet stripping automated endothelial keratoplasty using donor corneas with previous laser in situ keratomileusis or photorefractive keratectomy: a case series and donor cap histopathology. Cornea. 2012; 31(5): 533-7.
  8. Jester J.V., Villasenor R.A., Schanzlin D.J., Cavanagh D. Variations in corneal wound healing after radial keratotomy: possible insights into the mechanisms of clinical complications and refractive effects. Cornea. 1992; 11(3): 191-9.
  9. Tseng S.H., Chen F.K. Morphological and fluorophotometric analysis of the corneal endothelium after radial keratotomy. Cornea. 1998; 17(5): 471-5.
  10. MacRae S.M., Rich L.F. Long-term effects of radial keratotomy on the corneal endothelium. J. Refract. Surg. 1998; 14(1): 49-52.
  11. Maharana P., Jhanji V., Vajpayee R.B. Inadvertent use of cornea with previous LASIK in deep lamellar keratoplasty. Optom. Vis. Sci. 2014; 91(3): 59-62.
  12. Cohen A., Lambert A., Coloma F., Rootman D. Two cases of a penetrating keratoplasty with tissue from a donor who had undergone LASIK surgery. Cornea. 2002; 21(1): 111-3.
  13. Ousley P., Terry M. Objective screening methods for prior refractive surgery in donor tissue. Cornea. 2002; 21(2): 181-8.
  14. Vannas S. Excision of the donor cornea instead of enucleation. Invest. Ophthalmol. 1975; 14(4): 293-5.
  15. Hudde T., Reinhard T., Moller M., Schelle C., Spelsberg H., Cepin A. et al. Corneoscleral transplant excision in the cadaver. experiences of the North Rhine Westphalia Lions cornea bank 1995 and 1996. Ophthalmologe. 1997; 94(11): 780-4.
  16. Rootman D.B., Wankiewicz E., Sharpen L., Baxter S.A. In situ versus whole-globe harvesting of corneal tissue from remote donor sites: effects on initial tissue quality. Cornea. 2007; 26(3): 270-3.
  17. Abbott R.L., Fine M., Guillet E. Long-term changes in corneal endothelium following penetrating keratoplasty: a specular microscopic study. Ophthalmology. 1983; 90(6): 676-85.
  18. Culbertson W.W., Abbott R.L., Forster R.K. Endothelial cell loss in penetrating keratoplasty. Ophthalmology. 1982; 89(6): 600-4.
  19. Zacks C.M., Abbott R.L., Fine M. Long-term changes in corneal endothelium after keratoplasty: a follow-up study. Cornea. 1990; 9(2): 92-7.
  20. Bertelmann E., Pleyer U., Rieck P. Risk factors for endothelial cell loss post keratoplasty. Acta Ophthalmol. Scand. 2006; 84(6): 766-70.
  21. Musch D.C., Meyer R.F., Sugar A. Predictive factors for endothelial cell loss after penetrating keratoplasty. Arch. Ophthalmol. 1993; 111(1): 80-3.
  22. Ruusuvaara P. Effect of corneal preservation, donor age, cadaver time and postoperative period on the graft endothelium: a specular microscopic study. Acta Ophthalmol. (Copenh). 1979; 57(5): 868-81.
  23. Patel S.V., Hodge D.O., Bourne W.M. Corneal endothelium and postoperative outcomes 15 years after penetrating keratoplasty. Am. J. Ophthalmol. 2005; 139(2): 311-9.
  24. Agarwal A., Agarwal A., Narang P., Kumar D., Jacob S. Pre-descemet endothelial keratoplasty with Infant donor corneas: a prospective analysis. Cornea. 2015; 34(8): 859-65.
  25. Huang T., Wang Y., Hu A., Chen J. Use of pediatric donor tissue in Descemet’s stripping endothelial keratoplasty. Br. J. Ophthalmol. 2009; 93(12): 1625-8.
  26. Kim P., Yeung S.N., Lichtinger A., Amiran M.D., Rootman D.S. Descemet stripping automated endothelial keratoplasty using infant donor tissue. Cornea. 2012; 31(1): 52-4.
  27. Sun Y.X., Hao Y.S., Hong J. Descemet membrane stripping endothelial keratoplasty with neonate donors in two cases. Br. J. Ophthalmol. 2009; 93(12): 1692-3.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2016 Eco-Vector


 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».