Treatment of comminuted fractures of the bones of the lower leg with rod and pincer apparatus
- Authors: Gorodnichenko A.I.1, Uskov O.N.1
-
Affiliations:
- Educational and Scientific Center of the Medical Center of the Administration of the President of the Russian Federation
- Issue: Vol 7, No 4 (2000)
- Pages: 8-12
- Section: Original study articles
- URL: https://journal-vniispk.ru/0869-8678/article/view/104409
- DOI: https://doi.org/10.17816/vto104409
- ID: 104409
Cite item
Full Text
Abstract
From 1997 to 1999 thirty eight patients with splintered and polyfocal crus fractures (9 patients had open fractures) were treated by transosseous osteosynthesis using rod or pin-rod devices. Splintered diaphyseal fractures were of В and C groups according to AO/ASIF classification but peri- and intraarticular fractures were of A2,3 and C groups. In fractures with large intermediate fragments an universal reposition device with «floating» fixators of rods was applied. In cases of peri- and intraarticular fractures as well as in fractures with small intermediate fragments Gorodnichenko’s pin-rod device was used. The device provided stable fixation and patients with diaphyseal crus fractures were allowed full weight bearing from 3-5 postoperative day. The operative intervention is a low traumatic one that promotes early postoperative mobilization of patients, decreases the term of hospital treatment (mean 8.9 days). Fracture healing was achieved in all patients, no complications such as the imfiammation of soft tissues surrounding pins or rods were observed. The fixation was 12-18 weeks.
Keywords
Full Text
##article.viewOnOriginalSite##About the authors
A. I. Gorodnichenko
Educational and Scientific Center of the Medical Center of the Administration of the President of the Russian Federation
Author for correspondence.
Email: info@eco-vector.com
Russian Federation, Moscow
O. N. Uskov
Educational and Scientific Center of the Medical Center of the Administration of the President of the Russian Federation
Email: info@eco-vector.com
Russian Federation, Moscow
References
- Городниченко А.И., Гаврюшенко Н.С., Казаков М.Е., Керничанский В.М. //Вестн. травматол. ортопед. — 1999.— N 4.— С. 49-52.
- Городниченко А.И., Миронов С.П. //Современные технологии в травматологии и ортопедии: Материалы науч. конф., посвященной 75-летию со дня рождения К.М. Сиваша. — М.,1999. — С. 63-64.
- Малахов О.А., Кожевников О.В., Леванова И.В. //Там же. — С. 86-87.
- Миронов С.П., Городниченко А.И. //Новые имплантаты и технологии в травматологии и ортопедии: Материалы конгресса травматологов ортопедов России с международным участием. — Ярославль,1999. — С. 265-266.
- Пат. 2125417 РФ. Устройство для чрескостного остеосинтеза /Городниченко А.И., Казаков М.Е., Керничанский В.М., Лахтиков С.М.
- Пат. 2139006 РФ. Аппарат для чрескостного остеосинтеза /Городниченко А.И., Казаков М.Е., Керничанский В.М.
- Пат. 2155010 РФ. Спицестержневой аппарат для лечения внутри- и околосуставных переломов длинных костей /Городниченко А.И.
- Попсуйшапка А.К. //Ортопед. травматол. — 1991. — N7. —С. 52-53.
- Фаддеев Д.И. Ранний металлоостеосинтез закрытых и открытых множественных и сочетанных переломов длинных трубчатых костей. — Смоленск,1997.
- Фурдюк В.В. Остеосинтез переломов длинных трубчатых костей стержневыми аппаратами при политравме: Дис.... канд. мед. наук. — М.,1992.
- Chevalley F., Amsutz Ch., Bally A. //J. Orthop. Surg. — 1993.— N 1. —P. 1-7.
- Hierholzer G., Ruedi T., Allgower M., Schatzker J. Manual on the АО/ASIF tubular external fixator. — Berlin,1985.