Skin Effect Estimation in Radiofrequency Coils for Nuclear Magnetic Resonance Applications
- 作者: Giovannetti G.1,2, Tiberi G.3,4
- 
							隶属关系: 
							- Institute of Clinical Physiology, National Council of Research
- Fondazione G. Monasterio CNR
- Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, IRCCS Stella Maris Foundation
- Imago7 Foundation
 
- 期: 卷 47, 编号 6 (2016)
- 页面: 601-612
- 栏目: Review
- URL: https://journal-vniispk.ru/0937-9347/article/view/247474
- DOI: https://doi.org/10.1007/s00723-016-0780-x
- ID: 247474
如何引用文章
详细
The design and development of dedicated radiofrequency (RF) coils is a fundamental task to maximize the signal-to-noise ratio (SNR) in nuclear magnetic resonance (NMR) applications. Coil resistance reduces the SNR and should be minimized by employing conductors of appropriate shape and cross section. At RF, the conductor resistance is increased due to the skin effect, which distributes the current primarily on the surface of the conductor instead of uniformly over the cross section. In particular, in rectangular shape conductors the current density is concentrated in the high-curvature area and increases the conductor resistance, while rounded conductors present lower resistance and demonstrate improvements in performance especially in low-frequency tuned coils. This paper summarizes the different methods for estimating conductor losses in RF coils for NMR applications, whose performance strongly affect quality data. Because the impact to coil loss from conductors with different cross-sectional area is not something generally recognized and nor addressed in many other coil design works, we believe the review could be interesting for researchers working in the field of NMR coil design and development.
作者简介
Giulio Giovannetti
Institute of Clinical Physiology, National Council of Research; Fondazione G. Monasterio CNR
							编辑信件的主要联系方式.
							Email: giovannetti@ifc.cnr.it
				                					                																			                												                	意大利, 							Via Moruzzi 1, 56124 S. Cataldo, Pisa; Regione Toscana, Pisa						
Gianluigi Tiberi
Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, IRCCS Stella Maris Foundation; Imago7 Foundation
														Email: giovannetti@ifc.cnr.it
				                					                																			                												                	意大利, 							Pisa; Pisa						
补充文件
 
				
			 
						 
						 
					 
						 
						 
				 
  
  
  
  
  电邮这篇文章
			电邮这篇文章  开放存取
		                                开放存取 ##reader.subscriptionAccessGranted##
						##reader.subscriptionAccessGranted## 订阅存取
		                                		                                        订阅存取
		                                					