Quantitative Effect of Magnetic Field Strength on PEGylated Superparamagnetic Iron Oxide Nanoparticles
- Авторлар: Farzadniya A.1, Faeghi F.2, Shanehsazzadeh S.3
- 
							Мекемелер: 
							- Radiology Department, School of Allied Medical Sciences, Student’s Research Committee, Shahid Beheshti University of Medical Sciences
- Radiology Department, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences
- NMR and Molecular Imaging Laboratory, Department of General, Organic, and Biomedical Chemistry, University of Mons
 
- Шығарылым: Том 48, № 6 (2017)
- Беттер: 597-607
- Бөлім: Original Paper
- URL: https://journal-vniispk.ru/0937-9347/article/view/247704
- DOI: https://doi.org/10.1007/s00723-017-0880-2
- ID: 247704
Дәйексөз келтіру
Аннотация
With promising applications of superparamagnetic iron oxide nanoparticles (SPIO) in magnetic resonance imaging (MRI) and targeted monitoring of molecular and cellular processes, many different samples of these nanoparticles (NPs) with different compositions synthesized each year. The main challenge in this way is to generate enough contrast that could be traceable on images. In order to compensate for the low quantity of contrast agents in desired sites, surface engineering has to be done to enhance relaxation rates. As many factors such as magnetic field strength can affect relaxation rates of NPs, knowledge of the relation between field strength and relaxation rates is essential to compare results of different fields and choosing an optimum agent for a specific field. In this study, we evaluate the effects of magnetic field strengths of 0.35, 1.5, and 3 T on relaxation rates of PEGylated SPIOs. Longitudinal and transverse relaxation rates of all samples with various concentrations were analyzed quantitatively on appropriate spin–echo sequences. Our results suggest that the increasing of the field strength leads to a marked decrease of longitudinal relaxivity. In the case of transverse relaxivity, all NPs showed an increase between 0.35 and 1.5 T. Upon further increasing the field strength, relaxation rates only slightly increased except for two samples that showed saturation.
Негізгі сөздер
Авторлар туралы
Amin Farzadniya
Radiology Department, School of Allied Medical Sciences, Student’s Research Committee, Shahid Beheshti University of Medical Sciences
														Email: f_faeghi@sbmu.ac.ir
				                					                																			                												                	Иран, 							Tehran						
Fariborz Faeghi
Radiology Department, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences
							Хат алмасуға жауапты Автор.
							Email: f_faeghi@sbmu.ac.ir
				                					                																			                												                	Иран, 							Tehran						
Saeed Shanehsazzadeh
NMR and Molecular Imaging Laboratory, Department of General, Organic, and Biomedical Chemistry, University of Mons
														Email: f_faeghi@sbmu.ac.ir
				                					                																			                												                	Бельгия, 							Avenue Maistriau, 19, Mons, 7000						
Қосымша файлдар
 
				
			 
						 
						 
						 
					 
						 
									 
  
  
  
  
  Мақаланы E-mail арқылы жіберу
			Мақаланы E-mail арқылы жіберу  Ашық рұқсат
		                                Ашық рұқсат Рұқсат берілді
						Рұқсат берілді Тек жазылушылар үшін
		                                		                                        Тек жазылушылар үшін
		                                					