Square wave voltammetry for analytical determination of paracetamol using cobalt microparticles film modified platinum electrode


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Cobalt microparticles (Co MPs) modified Pt electrode is simply and conveniently fabricated. The electrochemical properties of paracetamol (PCT) at the prepared modified electrode are investigated using cyclic voltammetry (CV) and square wave voltammetry (SWV) measurements. Based on these techniques, a sensitive and rapid electrochemical method is developed for the determination of PCT. The result indicates that the oxidation of PCT is strongly improved at the Co MPs/Pt electrode as compared with the bare Pt electrode, with relatively high sensitivity, stability and life time. The determination of PCT on the Co MPs/Pt with square wave voltammetry displays a high sensitivity of 101 μA/mM and a low detection limit of 0.42 μM (S/N = 3) in the range (0.5–100 μM). The sensitivity of the modified electrode for the detection of PCT is almost 17 times greater than on the bare Pt electrode. The proposed method is successfully applied to the PCT determination in tablets.

About the authors

Merzak Doulache

Faculty of Sciences, (UATL)

Author for correspondence.
Email: doulache@yahoo.fr
Algeria, Laghouat, 03000

Boubakeur Saidat

Faculty of Sciences, (UATL)

Email: doulache@yahoo.fr
Algeria, Laghouat, 03000

Mohamed Trari

Faculty of Chemistry, (USTHB)

Email: doulache@yahoo.fr
Algeria, Algiers, 16111

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2017 Pleiades Publishing, Ltd.