Choice of Fine Packing for Rectification of Uranium Hexafluoride
- Authors: Ezhov V.K.1
-
Affiliations:
- National Research Center Kurchatov Institute
- Issue: Vol 123, No 2 (2017)
- Pages: 111-116
- Section: Article
- URL: https://journal-vniispk.ru/1063-4258/article/view/248665
- DOI: https://doi.org/10.1007/s10512-017-0310-4
- ID: 248665
Cite item
Abstract
Coefficients are proposed for the Bain–Hougen equation for calculating the limit velocity of vapor in a column filled with fine packing for the rectification of metal hexafluorides and their mixtures. It is shown that a simple method of comparing different packings in terms of the kinetic and hydrodynamic parameters is possible by using the effective throughput per unit volume of the packing, equivalent to one transfer unit.
About the authors
V. K. Ezhov
National Research Center Kurchatov Institute
Email: j-atomicenergy@yandex.ru
Russian Federation, Moscow
Supplementary files