Computational Error Using Monoenergetic Photon Source Data for Linear Electron Accelerator Shielding


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The dose error determined on the basis of recommendations for calculating the shielding of electron accelerators is determined by comparing the photon dose distribution calculated by the Monte Carlo method in concrete, iron, and lead from isotropic monoenergetic sources and sources with the bremsstrahlung spectrum of electron accelerators with energy above 15 MeV. It is shown that the highest error in using the mono-energetic sources to simulate sources of bremsstrahlung is observed for concrete protection and the smallest error is observed for lead. Suggestions are formulated for reducing the errors by means of individual selection of the effective energy of an equivalent monoenergetic source as a function of the energy of the accelerator electrons and the employed material.

作者简介

O. Propalova

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

V. Sakharov

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

I. Solov’ev

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

S. Chaikina

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, part of Springer Nature, 2018