Removal Efficiency of Cu2+ and Zn2+ from Industrial Wastewater by Using Microbial Desalination Cell


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The removal of Cu2+ and Zn2+ from industrial wastewater using the microbial desalination cell is studied. Both synthetic and industrial samples were haracterised in accordance with standard methods recommended for examination of water and wastewater. Synthetic samples used for the analysis were prepared with concentration 5; 25; 50; 75; 100 mg/L Cu2+ and Zn2+ in deionized water. The removal efficiency of each metal was analyzed after 30; 60; 90; 120; 150 min; psychrophilic, mesophilic, thermophilic and 2–3; 3–4; 4–5; 5–6 and 6–7 mg/L dissolved oxygen were monitored. The experiments were done on wastewater of electroplating industries in Isfahan, Iran, in optimum conditions. For data analysis, SPSS version 16 software was used. Optimum condition for removing Cu2+ and Zn2+ were found to be: 100 mg/L, 4.4 mg/L dissolved oxygen, 26°C and 120 min.

Sobre autores

Masha Malakootian

Pharm.D., PGY-1 Pharmacy Resident

Email: m.malakootian@yahoo.com
Estados Unidos da América, San Francisco, CA

Fariba Mirzaienia

Environmental Health Engineering Research Center

Email: m.malakootian@yahoo.com
Irã, Kerman

Mohammad Malakootian

Environmental Health Engineering Research Center; Department of Environmental Health, School of Public Health

Autor responsável pela correspondência
Email: m.malakootian@yahoo.com
Irã, Kerman; Kerman

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Allerton Press, Inc., 2019