Removal Efficiency of Cu2+ and Zn2+ from Industrial Wastewater by Using Microbial Desalination Cell


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The removal of Cu2+ and Zn2+ from industrial wastewater using the microbial desalination cell is studied. Both synthetic and industrial samples were haracterised in accordance with standard methods recommended for examination of water and wastewater. Synthetic samples used for the analysis were prepared with concentration 5; 25; 50; 75; 100 mg/L Cu2+ and Zn2+ in deionized water. The removal efficiency of each metal was analyzed after 30; 60; 90; 120; 150 min; psychrophilic, mesophilic, thermophilic and 2–3; 3–4; 4–5; 5–6 and 6–7 mg/L dissolved oxygen were monitored. The experiments were done on wastewater of electroplating industries in Isfahan, Iran, in optimum conditions. For data analysis, SPSS version 16 software was used. Optimum condition for removing Cu2+ and Zn2+ were found to be: 100 mg/L, 4.4 mg/L dissolved oxygen, 26°C and 120 min.

作者简介

Masha Malakootian

Pharm.D., PGY-1 Pharmacy Resident

Email: m.malakootian@yahoo.com
美国, San Francisco, CA

Fariba Mirzaienia

Environmental Health Engineering Research Center

Email: m.malakootian@yahoo.com
伊朗伊斯兰共和国, Kerman

Mohammad Malakootian

Environmental Health Engineering Research Center; Department of Environmental Health, School of Public Health

编辑信件的主要联系方式.
Email: m.malakootian@yahoo.com
伊朗伊斯兰共和国, Kerman; Kerman