Wide-range structurally optimized channel for monitoring the certified power of small-core reactors


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The results of tests of a prototype version of a channel for monitoring the certified power of small-core reactors performed at the BR-K1 reactor at the All-Russian Scientific Research Institute of Experimental Physics are reported. An SNM-11 counter and commercial KNK-4 and KNK-3 compensated ion chambers were used as neutron detectors in the tested channel, and certified NCMM and CCMM measurement modules controlled by a PC with specialized software were used as measuring instruments. The specifics of metrological assurance of calibration of the channel in the framework of reactor power monitoring are discussed.

作者简介

A. Koshelev

Russian Federal Nuclear Center—All-Russian Scientific Research Institute of Experimental Physics

编辑信件的主要联系方式.
Email: alexsander.coshelev@yandex.ru
俄罗斯联邦, Sarov, Nizhny Novgorod oblast, 607188

K. Kovshov

Russian Federal Nuclear Center—All-Russian Scientific Research Institute of Experimental Physics

Email: alexsander.coshelev@yandex.ru
俄罗斯联邦, Sarov, Nizhny Novgorod oblast, 607188

M. Ovchinnikov

Russian Federal Nuclear Center—All-Russian Scientific Research Institute of Experimental Physics

Email: alexsander.coshelev@yandex.ru
俄罗斯联邦, Sarov, Nizhny Novgorod oblast, 607188

G. Pikulina

Russian Federal Nuclear Center—All-Russian Scientific Research Institute of Experimental Physics

Email: alexsander.coshelev@yandex.ru
俄罗斯联邦, Sarov, Nizhny Novgorod oblast, 607188

A. Sokolov

Russian Federal Nuclear Center—All-Russian Scientific Research Institute of Experimental Physics

Email: alexsander.coshelev@yandex.ru
俄罗斯联邦, Sarov, Nizhny Novgorod oblast, 607188

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2016