Thermal Neutron Detectors for IBR-2 Spectrometers
- 作者: Bogdzel A.A.1, Kruglov V.V.1, Milkov V.M.1, Panteleev T.T.1, Churakov A.V.1
-
隶属关系:
- Frank Laboratory of Neutron Physics
- 期: 卷 81, 编号 10 (2018)
- 页面: 1465-1470
- 栏目: Engineering Design of Nuclear Physics Equipment
- URL: https://journal-vniispk.ru/1063-7788/article/view/193937
- DOI: https://doi.org/10.1134/S1063778818100022
- ID: 193937
如何引用文章
详细
The article reviews thermal neutron detector developments in the Department of the IBR-2 Spectrometer Complex of the Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research (FLNP JINR). A variety of detector types are considered: neutron monitors, ring detectors, position-sensitive detectors (PSD), and scintillation detectors. The experience of exploitation of these detectors at the research facilities of the FLNP JINR is presented.