Transients at Current Overloading in an Alternating Current Circuit with HTSC Wire


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

It has been established that the loss of superconductivity in high-temperature superconductor wires at alternating current overloading is accompanied by changing the phase difference sign between current and voltage. In a second-generation stabilized HTSC wire with overloading, oscillations of the amplitudes of the alternating current and voltage have been observed due to variations in the size of the normal zone in the superconducting layer. A change in the phase difference sign can be used for the timely registration of the normal zone formation in the current-carrying elements of superconducting electrical equipment.

About the authors

V. A. Malginov

Lebedev Physical Institute, Russian Academy of Sciences

Author for correspondence.
Email: malginovva@lebedev.ru
Russian Federation, Moscow, 119333

A. V. Malginov

Lebedev Physical Institute, Russian Academy of Sciences

Email: malginovva@lebedev.ru
Russian Federation, Moscow, 119333

L. S. Fleishman

Krzhizhanovsky Power Engineering Institute; Ordzhonikidze Russian State Geological Prospecting University

Email: malginovva@lebedev.ru
Russian Federation, Moscow, 119071; Moscow, 117997

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2019 Pleiades Publishing, Ltd.