Current distribution in a liquid electrospray system with two counter-electrodes


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

We have experimentally studied the distribution of current in an electrospray system with two counter-electrodes. It is established that, at low values of the total current, its distribution between these electrodes is proportional to the electric field flux to a given electrode. As the total current grows, this proportionality changes toward more uniform distribution, probably, due to increased role of a space charge producing mutual repulsion of charged particles.

作者简介

I. Gromov

Peter the Great St. Petersburg Polytechnic University; Institute for Analytical Instrument Making

编辑信件的主要联系方式.
Email: kolomna.88@mail.ru
俄罗斯联邦, St. Petersburg, 195251; St. Petersburg, 190103

N. Samsonova

Ioffe Physical Technical Institute; Institute for Analytical Instrument Making

Email: kolomna.88@mail.ru
俄罗斯联邦, St. Petersburg, 194021; St. Petersburg, 190103

L. Gall

Institute for Analytical Instrument Making

Email: kolomna.88@mail.ru
俄罗斯联邦, St. Petersburg, 190103

N. Gall

Ioffe Physical Technical Institute; Institute for Analytical Instrument Making

Email: kolomna.88@mail.ru
俄罗斯联邦, St. Petersburg, 194021; St. Petersburg, 190103

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2017