Ignition of droplets of coal–water–oil mixtures based on coke and semicoke
- Авторы: Vershinina K.Y.1, Glushkov D.O.1, Strizhak P.A.1
-
Учреждения:
- Tomsk Polytechnic University
- Выпуск: Том 60, № 1 (2017)
- Страницы: 28-36
- Раздел: Coke
- URL: https://journal-vniispk.ru/1068-364X/article/view/226163
- DOI: https://doi.org/10.3103/S1068364X17010082
- ID: 226163
Цитировать
Аннотация
To permit expansion of the resource base and utilize industrial waste, coal–water–oil fuels may be prepared on the basis of coke and semicoke, as well as common petroleum derivatives (fuel oil and spent compressor, turbine, and transformer oils). The minimal oxidant temperature corresponding to stable ignition of coal–water–oil slurries is established. Typical variation in fuel temperature in the course of reaction is determined, as well as the delay time of ignition and the total combustion time for individual droplets of such fuel suspensions. For droplets of initial size 0.5–1.5 mm, the influence of the various factors (droplet size, oxidant temperature, and concentration of the components) on the threshold (minimum) temperature and inertia of ignition is studied. It is shown that stable ignition of coke and semicoke in such fuel is possible at moderate oxidant temperatures: 700–1000 K.
Ключевые слова
Об авторах
K. Vershinina
Tomsk Polytechnic University
Автор, ответственный за переписку.
Email: vershininaks@gmail.com
Россия, Tomsk
D. Glushkov
Tomsk Polytechnic University
Email: vershininaks@gmail.com
Россия, Tomsk
P. Strizhak
Tomsk Polytechnic University
Email: vershininaks@gmail.com
Россия, Tomsk
Дополнительные файлы