Eliminating Liquid Entrapment between the Teeth of a Gear-Driven Pump
- Authors: Gorlenko O.A.1, Shalygin M.G.1, Makarov G.N.1
-
Affiliations:
- Bryansk State Technical University
- Issue: Vol 38, No 7 (2018)
- Pages: 499-502
- Section: Article
- URL: https://journal-vniispk.ru/1068-798X/article/view/227475
- DOI: https://doi.org/10.3103/S1068798X18070079
- ID: 227475
Cite item
Abstract
Entrapment of liquid in the intertooth space of a gear-driven pump is considered. A method is proposed for its elimination. The influence of annular channels on the volume losses in the pump is shown. The decrease in pump efficiency in the presence of annular channels is assessed.
About the authors
O. A. Gorlenko
Bryansk State Technical University
Email: makarov_g.n.89@mail.ru
Russian Federation, Bryansk
M. G. Shalygin
Bryansk State Technical University
Email: makarov_g.n.89@mail.ru
Russian Federation, Bryansk
G. N. Makarov
Bryansk State Technical University
Author for correspondence.
Email: makarov_g.n.89@mail.ru
Russian Federation, Bryansk
Supplementary files