Counter of the Remaining Life of Convection and Platen Steam Superheaters


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Aphysical-and-mathematical model of the counter of the remaining life of convection and platen superheaters based on standard measurements of steam conditions is presented. The model is based on the equations of heat transfer to steam, thermal conduction, high-temperature oxidation resistance, and stress-rupture of boiler steels. The calculated results on the life of the high-pressure convective superheater of TGMP-314 once-through boiler are presented.

About the authors

V. A. Bogachev

All-Russian Thermal Engineering Institute

Author for correspondence.
Email: bogachev_vti@rambler.ru
Russian Federation, Moscow

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature