Causes of Erosion-Induced Damage to Elements of Low-Pressure Evaporator Circuits of the Heat-Recovery Boilers of Combined-Cycle Power Plants
- Autores: Belyakov I.I.1, Breus V.I.1, Popov M.S.1
-
Afiliações:
- JSC Polzunov Scientific and Development Association for Research and Design of Power Equipment
- Edição: Volume 53, Nº 1 (2019)
- Páginas: 78-83
- Seção: Article
- URL: https://journal-vniispk.ru/1570-145X/article/view/246384
- DOI: https://doi.org/10.1007/s10749-019-01039-3
- ID: 246384
Citar
Resumo
An analysis of the causes of erosion-induced wear of the metal in pipe bends of evaporator heating pipe surfaces is performed based on experience gained from the operation of the heat-recovery boilers of combined-cycle (steam-gas) power plants. Damage to the evaporator tubes of a low-pressure boiling circuit is caused by the destruction of the protective oxide film due to intensive turbulization of the near-wall layer of water (which is at saturation temperature) travelling through the bend, inducing cavitation due to the formation of steam bubbles and their condensation. The protective oxide film formed in the hydrate water chemistry regime possesses the greatest stability.
Sobre autores
I. Belyakov
JSC Polzunov Scientific and Development Association for Research and Design of Power Equipment
Email: el.stantsii@gmail.com
Rússia, St. Petersburg
V. Breus
JSC Polzunov Scientific and Development Association for Research and Design of Power Equipment
Email: el.stantsii@gmail.com
Rússia, St. Petersburg
M. Popov
JSC Polzunov Scientific and Development Association for Research and Design of Power Equipment
Email: el.stantsii@gmail.com
Rússia, St. Petersburg
Arquivos suplementares