CLINICAL EXPERIENCE OF IRIS-CLAW IOL "ARTISAN" APPLICATION BEHIND THE IRIS IN POSTERIOR CHAMBER IN COMPLICATED CASES


Cite item

Full Text

Abstract

We followed-up 105 patients (107 eyes) at the age from 19 to 89 years (mean age 73.7+10.1 years) among them 63 (60%) females and 42 (40%) males. The follow-up term made from 4 to 96 months, in average - 20.4+19.8 months. Iris-claw IOL "ARTISAN" was implanted in all the patients behind the iris in posterior capsule. Visual acuity 0.5 and more was obtained in 90 (84.11%) cases. Iris-claw IOL implantation was accompanied by minimal complications. The position of the implanted lens remained stable during the whole follow-up period. Analysis of the clinical material and obtaining high functional results is evidence of safety and reliability of iris-claw IOL "ARTISAN" implantation behind the iris in posterior chamber in complicated cases; this procedure can be an operation of choice for aphakia correction.

About the authors

M A Frolov

Российский университет дружбы народов

Кафедра глазных болезнейд-р мед. наук, проф., зав. каф. глазных болезней; Российский университет дружбы народов

V Kumar

Российский университет дружбы народов

Кафедра глазных болезнейд-р мед. наук, проф., зав. каф. глазных болезней; Российский университет дружбы народов

P A Gonchar

Российский университет дружбы народов

Кафедра глазных болезнейд-р мед. наук, проф., зав. каф. глазных болезней; Российский университет дружбы народов

Edmond Isufay

Российский университет дружбы народов

Кафедра глазных болезнейаспирант каф. глазных болезнейГородская клническая больница № 12, отделение микрохирургии глаза; Российский университет дружбы народов

A A Dzhumova

Российский университет дружбы народов

Кафедра глазных болезнейаспирант каф. глазных болезней; Российский университет дружбы народов

M A Frolov

V Kumar

P A Gonchar

E Isufai

A A Jumova

References

  1. Егорова Э. В., Иошин И. Э., Толчинская А. И., Шахбазов А. Ф. Результаты имплантации коллагеновых ИОЛ с иридовитреальной фиксацией в отсутствие задней капсулы // Актуальные вопросы офтальмологии, Ч. 1: Сборник трудов научно-практической конф., посвящ. 170-летию Моск. офтальмологической клинической больницы. - М., 1996. - С. 142-144.
  2. Исуфай Э., Джуова А. А., Агзамова М. Д., Кумар В. Клинико-функциональные результаты интраокулярной коррекции афакии при отсутствии поддержки задней капсулы // II Всероссийская науч. конф. молодых ученых с участием иностранных специалистов "Актуальные проблемы офтальмологии": Сборник науч. статей / Под ред. Х. П. Тахчиди. - М., 2007. - С. 64-66.
  3. Кумар В. Особенности клинического течения послеоперационного периода при имплантации ИОЛ "клещевого захвата" // Актуальные вопросы воспалительных заболеваний глаз: Материалы науч.-практ. конф. МНИИГБ им. Гельмгольца, 20-21 нояб. 2001. - М., 2001. - С. 329-331.
  4. Малюгин Б. Э., Филипов В. О., Латыпов И. А. Интраокулярная линза с фиксацией на край капсулорексиса // Актуальные вопросы воспалительных заболеваний глаз: Материалы науч.-практ. конф. МНИИГБ им. Гельмгольца, 20-21 нояб. 2001. - М., 2001. - С. 59.
  5. Федоров С. Н., Егорова Э. В. Ошибки и осложнения при имплантации искусственного хрусталика. - М., 1999.
  6. Apple D. J., Brems R. N., Park R. B. et al. Anterior chamber lenses. Part I: Complications and pathology and a review of designs // J. Cataract Refract. Surg. - 1987. - Vol. 13. - P. 157-174.
  7. Condon G. P. Simplified small-incision peripheral iris fixation of an AcrySof intraocular lens in the absence of capsule support // J. Cataract Refract. Surg. - 2003. - Vol. 29. - P. 1663- 1667.
  8. Dick H. B., Augustin A. J. Lens implant selection with absence of capsular support // Curr. Opin. Ophthalmol. - 2001. - Vol. 12. - P. 47-57.
  9. Gimbel H., Condon G., Kohnen G. et al. Late in-the-bag intraocular lens dislocation: Incidence, prevention, and management // J. Cataract Refract. Surg. - 2005. - Vol. 31. - P. 2193-2204.
  10. Paul N. et al. Damaged or lost capsular bag // J. Cataract Refract. Surg. Today. - 2007. - P. 31-33.
  11. Por Y. M., Lavin M. J. Techniques of intraocular lens suspension in the absence of capsular/zonular support // Surv. Ophthalmol. - 2005. - Vol. 50. - P. 429-462.
  12. Wagoner M. D., Cox T. A., Ariyasu R. G. et al. Intraocular lens implantation in the absence of capsular support. A report by the American Academy of Ophthalmology // Ophthalmology. - 2003. - Vol. 110. - P. 840-859.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2010 Eco-Vector


 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».