Study of the quality of the marginal gap of artificial crown frames made with the use of traditional and digital technologies
- Authors: Zhulev E.N.1, Vokulova Y.A.2
-
Affiliations:
- Privolzhsky Research Medical University
- Federal state official institution “Polyclinic No. 2 of the Federal Сustoms Service of Russia”
- Issue: Vol 20, No 1-2 (2020)
- Pages: 85-90
- Section: Clinical Medicine
- URL: https://journal-vniispk.ru/2410-3764/article/view/54509
- DOI: https://doi.org/10.17816/2072-2354.2020.20.1.85-90
- ID: 54509
Cite item
Full Text
Abstract
The aim of the study is to evaluate the quality of the marginal gap of the frames of artificial crowns made with the use of CAD/CAM system and by casting method.
Materials and methods. The article presents an assessment of the quality of the edge fitting of artificial crown frames made by means of CAD/CAM system KaVo ARCTICA on digital images of dentition created by intraoral laser scanner iTero Cadent and frames made of Co-Cr by the method of casting. The Image J computer program was used to study the quality of the marginal gap of artificial crown frames. For statistical analysis of the obtained data nonparametric Wilcoxon-Mann-Whitney test was used for the evaluation of the related samples.
Results. We found that the average value of the marginal gap between the tooth stump of the experimental model and the frames of artificial crowns made in the KaVo ARCTICA Engine milling and grinding machine from the titanium blank Titan-Blank is 21.79 microns. The average value of the cement gap of the frames of artificial crowns made by the traditional casting method is 77.18 microns. The value of the marginal gap of artificial crown frames made by using the CAD/CAM system KaVo ARCTICA was 2.8 times less than the value of the marginal gap of frames made by the traditional casting method with a significance level of р < 0.05 (V-Wilcoxon criterion for related samples = 0, р = 0.001).
Conclusion. The results of our study indicate that the frames of artificial crowns made with the use of CAD/CAM system KaVo ARCTICA have a greater dimensional accuracy of the marginal gap compared to the frames of artificial crowns made by the traditional casting method.
Keywords
Full Text
##article.viewOnOriginalSite##About the authors
Evgenii N. Zhulev
Privolzhsky Research Medical University
Author for correspondence.
Email: hrustalev54@mail.ru
Professor, Department of Orthopaedic Dentistry and Orthodontics
Russian Federation, Nizhny NovgorodYuliya A. Vokulova
Federal state official institution “Polyclinic No. 2 of the Federal Сustoms Service of Russia”
Email: vokulova@rambler.ru
Head of the Dental Department, Stomatologist-Orthopedist
Russian Federation, Nizhny NovgorodReferences
- Вокулова Ю.А., Жулев Е.Н. Оценка точности получения оттисков зубных рядов с применением технологии лазерного сканирования // Современные проблемы науки и образования. – 2016. – № 5. – C. 164. [Vokulova YuA, Zhulev EN. Evaluation of the accuracy of obtaining impressions of the dentition with the use of technology of laser scanning. Modern problems of science and education. 2016;(5):164. (In Russ.)]
- Жулев Е.Н., Вокулова Ю.А. Изучение размерной точности цифровых оттисков, полученных с помощью внутриротового сканера iTero // Международный журнал прикладных и фундаментальных исследований. – 2016. – № 12-2. – С. 257–261. [Zhulev EN, Vokulova YuA. Evaluation of dimensional accuracy digital impressions obtained using the intraoral scanner Itero. International journal of applied and fundamental research. 2016;(12-2):257-261. (In Russ.)]
- Жулев Е.Н., Вокулова Ю.А. Сравнительная оценка размерной точности оттисков в эксперименте // Dental Forum. – 2017. – № 1. – С. 38–42. [Zhulev EN, Vokulova YuA. Sravnitel’naya otsenka razmernoy tochnosti ottiskov v eksperimente. Dental Forum. 2017;(1):38-42. (In Russ.)]
- Розенштиль С.Ф. Ортопедическое лечение несъемными протезами. – М.: Медпресс, 2010. – 940 с. [Rozenshtil’ SF. Ortopedicheskoye lecheniye nes”yemnymi protezami. Moscow: Medpress; 2010. 940 p. (In Russ.)]
- Ряховский А.Н. Цифровая стоматология. – М.: Авантис, 2010. – 282 с. [Ryakhovskiy AN. Tsifrovaya stomatologiya. Moscow: Avantis; 2010. 282 p. (In Russ.)]
- Шустова В.А., Шустов М.А. Применение 3D-технологий в ортопедической стоматологии. – СПб.: СпецЛит, 2016. – 159 с. [Shustova VA, Shustov MA. Primeneniye 3D-tekhnologiy v ortopedicheskoy stomatologii. Saint Petersburg: SpetsLit; 2016. 159 p. (In Russ.)]
- Ng J, Ruse D, Wyatt Ch. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. J Prosthet Dent. 2014;112(3):555-560. https://doi.org/10.1016/j.prosdent.2013.12.002.
Supplementary files
