Application of Hemostatic Agent “Haemoblock” for Pocket Hematoma Reduction. Design of the PEGAS study: a Multicenter Clinical Trial
- 作者: Nechepurenko A.A.1, Ilov N.N.2, Durmanov S.S.1, Shugaev P.L.1, Ivanchenko A.V.3, Suchkov I.A.4, Bsharat K.A.1, Lukin A.M.5, Medyanсeva L.G.1, Povarov V.O.6
-
隶属关系:
- Federal Center for Cardiovascular Surgery
- НЕ Astrakhan SMU МОН Russia
- Federal Center for high medical technologies
- Ryazan State Medical University
- Moscow Regional Scientific Research Institute of Blood
- Ryazan State Cardiological Dispensary
- 期: 卷 1, 编号 1 (2021)
- 页面: 17-24
- 栏目: Original Research
- URL: https://journal-vniispk.ru/cardar/article/view/70497
- DOI: https://doi.org/10.17816/cardar70497
- ID: 70497
如何引用文章
详细
Pocket hematoma (PH) is a common complication of pacemaker implantations which prolongs hospitalization and may demand surgical revision in some cases. According to the data from different researchers PH rate varies from 2 to 7%. It depends on number of factors including a need for anticoagulation therapy. We present a review of design of multicenter clinical trial evaluating safety and efficacy of application of hemostatic agent “Haemoblock” for pocket hematoma reduction in patients taking oral anticoagulants.
作者简介
Anatoly Nechepurenko
Federal Center for Cardiovascular Surgery
编辑信件的主要联系方式.
Email: vestik@mail.ru
ORCID iD: 0000-0001-5722-9883
SPIN 代码: 5582-8428
candidate of medical sciences
俄罗斯联邦, AstrakhanNikolay Ilov
НЕ Astrakhan SMU МОН Russia
Email: nikolay.ilov@gmail.com
ORCID iD: 0000-0003-1294-9646
SPIN 代码: 7426-3796
candidate of medical sciences
俄罗斯联邦, AstrakhanSergei Durmanov
Federal Center for Cardiovascular Surgery
Email: ssd58@yandx.ru
ORCID iD: 0000-0002-4973-510X
candidate of medical sciences
俄罗斯联邦, PenzaPavel Shugaev
Federal Center for Cardiovascular Surgery
Email: doc.shugaev@gmail.com
ORCID iD: 0000-0002-5055-6838
SPIN 代码: 7293-8980
candidate of medical sciences
俄罗斯联邦, ChelyabinskAndrey Ivanchenko
Federal Center for high medical technologies
Email: ivancha74@gmail.ru
ORCID iD: 0000-0001-5501-4926
俄罗斯联邦, Kaliningrad
Igor' Suchkov
Ryazan State Medical University
Email: suchkov_med@mail.ru
ORCID iD: 0000-0002-1292-5452
SPIN 代码: 6473-8662
doctor of medical sciences
俄罗斯联邦, RyazanKhosni Bsharat
Federal Center for Cardiovascular Surgery
Email: hosni@mail.ru
ORCID iD: 0000-0002-1366-9294
SPIN 代码: 1374-8371
candidate of medical sciences
俄罗斯联邦, KhabarovskAndrey Lukin
Moscow Regional Scientific Research Institute of Blood
Email: look7in@yandex.ru
俄罗斯联邦, Moscow
Lyudmila Medyanсeva
Federal Center for Cardiovascular Surgery
Email: medastra@rambler.ru
ORCID iD: 0000-0002-8485-6636
SPIN 代码: 5010-7870
candidate of medical sciences
俄罗斯联邦, AstrakhanVladislav Povarov
Ryazan State Cardiological Dispensary
Email: povarov.vladislav@mail.ru
ORCID iD: 0000-0001-8810-9518
SPIN 代码: 2873-1391
candidate of medical sciences
俄罗斯联邦, Ryazan参考
- Ilov N, Nechepurenko A, Abdulkadyrov A, et al. Arguments to apply epinephrine for pocket hematoma reduction. The MAITRE Study. J Atr Fibrillation. 2016;9(1):1391. doi: 10.4022/jafib.1391
- Notaristefano F, Angeli F, Verdecchia P, et al. Device-pocket hematoma after cardiac implantable electronic devices. Circ Arrhythm Electrophysiol. 2020;13(4):361–363. doi: 10.1161/CIRCEP.120.008372
- De Sensi F, Miracapillo G, Cresti A, et al. Pocket hematoma: a call for definition. Pacing Clin Electrophysiol. 2015;38(8):909–913. doi: 10.1111/pace.12665
- Essebag V, Verma A, Healey JS, et al. Clinically significant pocket hematoma increases long-term risk of device infection: BRUISE CONTROL INFECTION study. J Am Coll Cardiol. 2016;67(11): 1300–1308. doi: 10.1016/j.jacc.2016.01.009
- Sridhar ARM, Yarlagadda V, Yeruva MR, et al. Impact of haematoma after pacemaker and CRT device implantation on hospitalization costs, length of stay, and mortality: A popu-lation-based study. Europace. 2015;17(10):1548–1554. doi: 10.1093/europace/euv075
- Essebag V, Healey JS, Joza J, et al. Effect of direct oral anticoagulants, warfarin, and an-tiplatelet agents on risk of device pocket hematoma: Combined analysis of BRUISE CON-TROL 1 and 2. Circ Arrhythm Electrophysiol. 2019;12(10):e007545. doi: 10.1161/CIRCEP.119.007545
- Birnie DH, Healey JS, Wells GA, et al. Pacemaker or Defibrillator Surgery without Inter-ruption of Anticoagulation. N Engl J Med. 2013;368(22):2084–2093. doi: 10.1056/nejmoa1302946
- Sridhar ARM, Yarlagadda V, Kanmanthareddy A, et al. Incidence, predictors and out-comes of hematoma after ICD implantation: An analysis of a nationwide database of 85,276 patients. Indian Pacing Electrophysiol J. 2016;16(15):159–164. doi: 10.1016/j.ipej.2016.10.005
- Lucevich O.Eh. Peculiarities of application of local hemostatic materials in surgery. Moscow Surgical Journal. 2016;(3(49)):12–20. (In Russ.).
- Tereshchenko SG, Plotkin AV, Mecheva LV. Intraorgan use of Hemoblock for prevention and arrest of bleedings in endoscopic excision of gastric polyps. Russian Sklifosovsky Journal Emergency Medical Care. 2019;8(1):30–34. doi: 10.23934/2223-9022-2019-8-1-30-34
- Tscholl V, Spann F, Moses J, et al. Prospective randomized study evaluating the effects of PerClot® (Polysaccharide Hemostatic System) application in patients with high bleeding risk undergoing cardiac rhythm device implantation. Int J Cardiol. 2017;248:84–91. doi: 10.1016/j.ijcard.2017.08.038
- Reynbakh O, Akhrass P, Souvaliotis N, et al. Use of MPH hemostatic powder for elec-trophysiology device implantation reduces postoperative rates of pocket hematoma and infec-tion. Curr Med Res Opinion. 2018;34(10):1861–1867. doi: 10.1080/03007995.2018.1476847
- Degovtsov EN, Kolyadko PV, Kolyadko VP, Satinov AV. first results of a randomized controlled trial of hemoblock in patients with large incisional hernias. Russian Sklifosovsky Journal of Emergency Medical Care. 2019;8(4):430–436. (In Russ.). doi: 10.23934/2223-9022-2019-8-4-430-436
- Kolesov SV, Grin AA, Slinyakov LY, et al. Efficiency of using polyacrylic acid silver salt in decompression and stabilization surgery on the lumbar spine involving 1 to 3 segments. Spine Surgery. 2019;16(2):73–80. (In Russ.). doi: 10.14531/ss2019.2.73–80
- Revishvili ASh, Shlyakhto EV, Popov SV, et al. Clinical recommendations for the use of electrophysiological study, catheter ablation and implantable cardiac electronic devices. Moscow; 2017. (In Russ.).
- Makarova NV, Durmanov SS, Kozlov AV, et al. Does early activa-tion of patients after pacemaker implantation affect the rate of post-intervention complications? Journal of Arrhythmology. 2013;(74):40–44. (In Russ.).



