Results of calculations and experimental investigations of the refrigerator realizing a throttle cycle of Linde with the temperature in the refrigerated room from —60 to — 70 °C are presented. The refrigerator has been developed on the basis of commercially produced hermetic freon compressor charged with a blend refrigerant R14/R22/R23 instead ofR22.