Household absorption refrigerator with additional propane refrigeration unit
- Issue: Vol 89, No 12 (2000)
- Pages: 18-19
- Section: Articles
- URL: https://journal-vniispk.ru/0023-124X/article/view/107725
- DOI: https://doi.org/10.17816/RF107725
- ID: 107725
Cite item
Full Text
Abstract
Some results of the experimental investigation of a household absorption refrigerator where a propane refrigerating unit working on a closed throttle cycle is additinally used are presented. Several advantages are determined allowing to increase the efficiency of the absorption refrigerator and impart new qualities to it.
Full Text
##article.viewOnOriginalSite##References
Supplementary files
Supplementary Files
Action
1.
JATS XML
2.
Rice. 1. Scheme of an absorption refrigerator with a propane refrigeration unit: 1 - a cylinder with liquid propane; 2, 6 manual prim valves; 3 - filter-drier; 4 - heat exchanger; 5 - pressure reducer; 7 - additional burner; 8 - check valve; 9 - thermostat with manual setting; 10 - solenoid valve with manual adjustment; 11 - thermocouple; 12 - thermosyphon of the generator unit; 13 - rectifier; 14 - capacitor; 15 flame glass with electric heater; 16 - piezoelectric igniter; 17. 2 4 - unregulated chokes; 18 - main burner; 19 - absorber; 20 - gas heat exchanger; 21 - absorber tank; 22, 23 - evaporators; 25 - thermal bulb; 26 - refrigerator
Download (1MB)
3.
Rice. Fig. 2. Dependence of temperatures in the NTC (a) and CC (b) of the absorption refrigerator on the duration of reaching the regime with various energy sources: 1 - natural gas; 2 - electricity; 3 - natural gas (when using a propane choke cycle)
Download (1MB)