Analysis of blood plasma at terahertz frequencies
- Авторы: Cherkasova O.P.1, Nazarov M.M.2, Angeluts A.A.3, Shkurinov A.P.3
-
Учреждения:
- Institute of Laser Physics
- Institute on Laser and Information Technologies
- Lomonosov Moscow State University
- Выпуск: Том 120, № 1 (2016)
- Страницы: 50-57
- Раздел: Optics and Spectroscopy in Biophysics and Medicine
- URL: https://journal-vniispk.ru/0030-400X/article/view/165214
- DOI: https://doi.org/10.1134/S0030400X16010069
- ID: 165214
Цитировать
Аннотация
Terahertz time-domain spectroscopy in the 0.05-2.5 THz frequency range was employed to analyze blood plasma samples obtained from laboratory animals with experimental diabetes and from healthy controls. It was found that transmission and reflection coefficients of samples from rats with diabetes differed significantly from control values in both amplitude and phase. The cause of the detected differences is discussed with respect to variation in the terahertz response of water.