Fuel Utilization Monitoring Techniques for Large-Capacity Combined-Cycle Power Plants
- Авторлар: Ol’khovskii G.G.1, Trushechkin V.P.1, Ageev A.V.1, Tuz N.E.1, Teplov B.D.1, Rozhkov A.D.1
-
Мекемелер:
- All-Russia Thermal Engineering Institute
- Шығарылым: Том 66, № 5 (2019)
- Беттер: 316-322
- Бөлім: Steam Turbine, Gas Turbine, and Combined-Cycle Power Plants and Their Auxiliary Equipment
- URL: https://journal-vniispk.ru/0040-6015/article/view/173251
- DOI: https://doi.org/10.1134/S0040601519050070
- ID: 173251
Дәйексөз келтіру
Аннотация
A technique for calculating the standardized indicators characterizing the thermal efficiency of combined-cycle power plants (CCPPs) using correlation equations linking the values of these indicators with different external conditions is proposed. The correlation equations were written using the results from measuring the outdoor air and cooling water temperatures; air barometric pressure and humidity; fuel (natural gas) flowrate, heating value, and density and load in steady-state operation modes of the CCPPs and their equipment. It is usually sufficient to have a sample with three groups each representing 15–20 operating modes: under winter conditions at an outdoor air temperature of –20 to –30°С, under summer conditions at an outdoor air temperature of above 20 to 30°С, and at an intermediate temperature of ±5 to ±7°С. In each group, it is sufficient to have two operating modes each with loads close to 0.5, 0.6, 0.7, 0.8, and 0.9 of the maximal value, and 5–10 operating modes with a close-to-nominal load. It is shown, taking a single-shaft 400 MW CCPP as an example, that the correlation equations adequately (with errors equal to approximately 1%) describe the results obtained experimentally in the normal operation modes. The developed technique opens the possibility to determine, in a more accurate and simple manner, the standardized heat rates and other technical-economic indicators of fuel utilization without using an excessive number of corrections able to distort the result. The technique can also be used for estimating the changes of CCPP indicators as a result of taking some or other measures in them.
Авторлар туралы
G. Ol’khovskii
All-Russia Thermal Engineering Institute
Хат алмасуға жауапты Автор.
Email: vti@vti.ru
Ресей, Moscow, 115280
V. Trushechkin
All-Russia Thermal Engineering Institute
Email: vti@vti.ru
Ресей, Moscow, 115280
A. Ageev
All-Russia Thermal Engineering Institute
Email: vti@vti.ru
Ресей, Moscow, 115280
N. Tuz
All-Russia Thermal Engineering Institute
Email: vti@vti.ru
Ресей, Moscow, 115280
B. Teplov
All-Russia Thermal Engineering Institute
Email: vti@vti.ru
Ресей, Moscow, 115280
A. Rozhkov
All-Russia Thermal Engineering Institute
Email: vti@vti.ru
Ресей, Moscow, 115280
Қосымша файлдар