Key Comparison of the Standards for the Volt of the Russian Federation and the Republic of Belarus Using a Quantum Comparison Standard


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The procedure and results of key comparisons of the national voltage standards of the Russian Federation and the Republic of Belarus using a 10 V quantum comparison standard are discussed. The comparisons agree with the reference value obtained from the BIPM voltage standard. The relative difference was 0.9·10–10 with a combined relative standard uncertainty of 2.6·10–10.

About the authors

A. S. Katkov

Mendeleev All-Russia Research Institute of Metrology (VNIIM)

Author for correspondence.
Email: a.s.katkov@vniim.ru
Russian Federation, St. Petersburg

P. A. Chernyaev

Belarus State Institute of Metrology (BelGIM)

Email: a.s.katkov@vniim.ru
Belarus, Minsk

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2016 Springer Science+Business Media New York