Determining the position of hydrate blocks in gas pipelines by a radiowave method
- Authors: Zherlitsyn A.G.1, Shiyan V.P.1
-
Affiliations:
- Physical-Technical Institute
- Issue: Vol 52, No 10 (2016)
- Pages: 594-599
- Section: Radiowave Methods
- URL: https://journal-vniispk.ru/1061-8309/article/view/181207
- DOI: https://doi.org/10.1134/S1061830916100119
- ID: 181207
Cite item
Abstract
A radiowave method of detecting and positioning hydrate blocks in pipelines is considered. The method consists in probing a pipeline with a high-frequency nanosecond-duration radio pulse with subsequent measurement of its travel time to the hydrate block and back. Results of a natural experiment and flow charts of a device for determining the position of a hydrate block imitator (ice) in a stub pipe with a diameter of 273 mm. A Gunn diode is used as a generator of microwave pulses with a duration of 10 ns and a basic frequency of 10 GHz. The decay of microwave pulses in the pipe and the potential of the radiowave method are estimated.